ESD Control Guide: S20.20 Limits, HBM/CDM Classes, Measurement & Audit Checklist

What is ESD control?

ESD control — also called ESD protection or static control — is the program of grounding, dissipative materials, ionization and packaging that keeps electrostatic discharge damage to electronic parts at an acceptable level during manufacturing, handling and shipping. The two program standards widely cited are ANSI/ESD S20.20 (ESD Association) and IEC 61340-5-1 (IEC).

Both cover parts with withstand voltages of 100 V HBM and 200 V CDM or higher, and limit isolated conductors to below 35 V (ANSI/ESD S20.20-2021 clause 2; IEC 61340-5-1:2024 abstract on the IEC Webstore). More sensitive parts need additional controls or adjusted limits.

How static damages parts

A discharge between objects at different potentials can cause catastrophic failure (caught at test) or latent damage (the part passes, then fails in the field). Common charge sources on an electronics floor: people walking, garments, PCBs moving on conveyors, bubble wrap and film, plastic fixtures. Low winter humidity makes things worse.

There is no official annual figure; your own failure analysis data is the number that matters.

How sensitive is the part? HBM and CDM classes

HBM (ANSI/ESDA/JEDEC JS-001): 0Z <50 V; 0A 50–<125 V; 0B 125–<250 V; 1A 250–<500 V; 1B 500–<1000 V; 1C 1000–<2000 V; 2 2000–<4000 V; 3A 4000–<8000 V; 3B ≥8000 V (Thermo Fisher; EPC ESD report).

CDM (ANSI/ESDA/JEDEC JS-002): C0a <125 V; C0b 125–<250 V; C1 250–<500 V; C2a 500–<750 V; C2b 750–<1000 V; C3 ≥1000 V (Thermo Fisher).

JEDEC JEP155 states that 500 V HBM, and JEP157 that 250 V CDM, allow safe manufacturing with a standard ESD control process; lower levels are possible with additional precautions (TI datasheet footnotes; In Compliance Magazine, “ESD Target Levels: The Industry Council”).

Hypothetical: a part rated HBM ±2000 V and CDM ±500 V sits inside S20.20 scope. An RF part rated HBM 100 V and CDM 150 V falls below the 200 V CDM scope, so that station needs tighter, documented limits (tailoring).

ANSI/ESD S20.20-2021 technical requirements

Product qualification uses the listed ANSI/ESD test methods; compliance verification uses ESD TR53.

Clause 8.1 Grounding/bonding (Table 1, ANSI/ESD S6.1): equipment grounding conductor <1.0 Ω impedance; auxiliary ground <25 Ω to the equipment grounding conductor; equipotential bonding <1.0×10⁹ Ω to the common connection point.

Clause 8.2 Personnel grounding (Table 2):
– Wrist strap system: <3.5×10⁷ Ω (S1.1 for qualification, TR53 for verification).
– Footwear/flooring system: <1.0×10⁹ Ω (STM97.1) and body voltage <100 V peak (STM97.2) for qualification; <1.0×10⁹ Ω for verification.

Seated operators must wear wrist straps; standing operators may use either system (S20.20-2021; In Compliance Magazine 2014 review; Cofactr).

Clause 8.3 EPA control items (Table 3, summary):
– Worksurfaces (STM4.1): point-to-point and point-to-ground <1.0×10⁹ Ω; a lower limit of 1.0×10⁶ Ω may be considered for CDM concerns.
– Flooring (STM7.1): <1.0×10⁹ Ω.
– Seating (STM12.1): <1.0×10⁹ Ω.
– Ionization (STM3.1): offset voltage −35 V to +35 V; discharge time user-defined.
– Shelving and mobile equipment: same as worksurfaces.
– Static control garments (STM2.1): <1.0×10¹¹ Ω point-to-point; groundable garments <1.0×10⁹ Ω.
– Soldering irons (S13.1): tip-to-ground <2.0 Ω.

Clause 8.3.1 Insulators: non-essential insulators at least 300 mm from ESD-sensitive items; process-essential insulators must meet a field below 5000 V/m (125 V/inch), or surface voltage below 125 V within 25 mm and below 2000 V at 25–300 mm.

Clause 8.3.2 Isolated conductors: if they contact sensitive items, −35 V to +35 V relative to ground.

Clause 8.4 Packaging (Table 4): conductive <1.0×10⁴ Ω; dissipative ≥1.0×10⁴ to <1.0×10¹¹ Ω; shielding bags <20 nJ.

IEC 61340-5-1:2024 (Ed. 3.0, May 2024) keeps the same scope; listed changes include a replaced Table 2, an updated Table 3 referencing IEC 61340-5-4 for compliance verification, and a new Table 4 summarising packaging requirements (IEC Webstore). Check its numerical limits against the purchased text.

Measuring: worked examples (hypothetical data)

  • Wrist strap system: tester reads 8.5×10⁶ Ω → below 3.5×10⁷ Ω, pass.
  • Footwear/flooring qualification: 4.2×10⁸ Ω resistance passes, but a 135 V walking body voltage fails the 100 V limit, so the system fails — both limits apply.
  • Surface resistance: R = V / I. At 100 V and 2.0×10⁻⁷ A, R = 5.0×10⁸ Ω — inside the dissipative packaging range.
  • Which method? ANSI/ESD STM11.11 measures surface resistance of planar materials with a concentric ring electrode (ESDA table of contents) and is used mainly for material and packaging qualification. One qualification report conditioned samples 48–72 h at 23 °C, 12% and 50% RH, measured at 100 V. Worksurfaces, shelving and carts are checked with STM4.1 (point-to-point, point-to-ground), not STM11.11.
  • Ionizers: charged plate monitor reads +18 V offset → within ±35 V. Discharge time is judged against your own documented limit. A “±5 V” figure seen in product literature is an equipment spec, not the S20.20 limit.

EPA layout

  1. Mark the EPA boundary; test wrist straps and footwear at the entrance.
  2. Give every workstation a common connection point tied to equipment ground.
  3. Wrist straps for seated work, ESD footwear on both feet, static control garments.
  4. Groundable, measured worksurfaces, seating, shelving and carts.
  5. Move non-essential plastics out beyond 300 mm; neutralise process-essential insulators (laminate, film, plastic fixtures) with ionizers.
  6. Ship sensitive items out of the EPA in shielding bags or conductive totes.
  7. Measure and record on the schedule set in your compliance verification plan (ESD TR53 as reference).

Passive grounding vs active ionization

Grounding drains charge from conductors, including people. It does nothing for insulators — PCB laminate, packaging film, plastic fixtures — whose charge cannot flow to ground. Ionizers neutralise that charge, but emitter pins collect dust and the balance drifts, so they need periodic verification. The two layers work together.

Sample audit sheet (hypothetical data)

ItemMethodFrequency (example)LimitReadingResult
Wrist strap systemTester (TR53)Each shift<3.5×10⁷ Ω8.5×10⁶ ΩPass
Footwear/flooringTester (TR53)Each shift<1.0×10⁹ Ω2.1×10⁹ ΩFail — retest with new footwear
Worksurface RtgSTM4.1/TR53Monthly<1.0×10⁹ Ω3.0×10⁸ ΩPass
SeatingTR53Quarterly<1.0×10⁹ Ω7.0×10⁷ ΩPass
Ionizer offsetCPM (TR53)Monthly−35 to +35 V+42 VFail — clean emitters, retest
Process-essential insulatorField meterWeekly<125 V within 25 mm80 VPass
Equipotential bondingS6.1At setup and changes<1.0×10⁹ Ω1.5×10⁶ ΩPass

S20.20 does not set one universal verification frequency; the organisation defines it (Cofactr).

Common mistakes

  1. Treating wrist straps as the whole program.
  2. Assuming cleanrooms have no static problem.
  3. Installing ionizers and never re-verifying balance.
  4. Never re-measuring worksurfaces after wear, contamination or cleaner residue.
  5. Judging a worksurface with an STM11.11 surface-resistance number instead of STM4.1 resistance-to-ground.
  6. Quoting “±100 V surface potential” as the limit — S20.20 sets 125 V/2000 V for insulators and 35 V for isolated conductors.
  7. Not reading the part’s HBM/CDM rating; parts below 200 V CDM fall outside standard scope.

Where this applies

SMT lines (placement machine loading, reflow exit, AOI), ICT and functional test stations with plastic fixtures, cleanroom packing areas, incoming inspection of sensitive parts, rework and repair benches.

Jiahon supplies wrist straps, ESD mats, ionizers and ESD gloves. Send us your floor conditions (area, humidity, part HBM/CDM ratings) and we can help put together a grounding-plus-ionization setup. Final limits follow the current edition of the standard you adopt and the component manufacturer’s datasheet.

FAQ

What is ESD control? A program of grounding, dissipative materials, ionization and packaging; S20.20 and IEC 61340-5-1 cover parts ≥100 V HBM and ≥200 V CDM.

What resistance should a wrist strap system read? Below 3.5×10⁷ Ω (S20.20-2021 Table 2).

What are the footwear/flooring limits? Below 1.0×10⁹ Ω, plus body voltage below 100 V peak at qualification.

What ionizer balance does S20.20 require? Offset −35 V to +35 V; discharge time user-defined.

How many parts does static destroy each year? No official annual figure; use your own failure analysis data.

References

See the reference list in the Chinese version (ANSI/ESD S20.20-2021; In Compliance Magazine; Cofactr; IEC Webstore; Thermo Fisher; EPC; Texas Instruments; ESDA STM11.11 TOC; Desco).