JIAHON case study · Passive ESD protection
An EMS plant’s integrated ESD protection and clean work environment project | Rebuilding a complete protection chain with four items
Passive ESD protection needs at least four items joined into one ground path: an antistatic table mat (work surface), a wrist strap (operator’s hands), a heel strap or ESD shoes (operator’s feet), and a grounded workbench. Leave one out and static has no fixed path to drain.
Grounded floors and ESD garments already in place, but ESD problems keep coming back? The problem is often not whether protection exists, but whether the protection chain is closed. A table that is not grounded, a broken wrist strap cord, a heel strap that fails when the operator moves — break any link and the whole passive protection system might as well not be there.
For the full theoretical framework of ESD protection (including active protection), see: → “The Complete ESD Protection Guide: Is Passive Dissipation Enough, or Is Active Neutralization the Key?”
1. Background: the equipment was there, but the protection chain was not closed
The EMS plant mainly produces sensor modules and communication controllers, with many ESD-sensitive components (ESDS components) in its products. Although the plant had grounded floors and ESD garments, it lacked complete grounding integration at the workstations, which led to four specific problems:
| Symptom | Root cause |
|---|---|
| Instantaneous discharges during assembly and test | Operators not reliably grounded; breaks in the wrist strap or heel strap chain |
| High measurement error on test fixtures | Uneven table surface potential; workbench not connected to the ground network |
| High false call rates at AOI and ICT | Local charge buildup in work areas affecting test signal stability |
| Unstable static discharge path | Cleanroom workbenches not connected to the plant grounding system |
JIAHON proposed a modular integrated solution, rebuilding a complete “person → table surface → floor” ground chain with four items.
The closed protection chain: person (seated) — wrist strap; person (moving) — heel strap; table surface — antistatic table mat; workbench backbone — cleanroom workbench; floor ground — plant grounding system.
2. The solution: specifications and effect of the four items
| Antistatic table mat (ESD table mat) |
|---|
| • Two-layer conductive rubber structure |
| • Surface resistance 10⁶–10⁸ Ω |
| • Resistant to alcohol, IPA and flux solutions |
| • 10 mm conductive snap for grounding, with ground continuity verified against the limits in IEC 61340-5-1 |
| ✓ Table resistance 10¹⁰ → 10⁷ Ω (down three orders of magnitude) |
| Antistatic wrist strap (ESD wrist strap) |
|---|
| • Woven conductive fiber, with stainless steel wire for conduction on the inside |
| • Adjustable length, low contact resistance |
| • For continuous grounding during seated work |
| ✓ Personnel potential ±280 V → ±12 V (−96%) |
| ✓ Designed for use with JESD625 ESD control programs |
| Heel strap (ESD heel strap) |
|---|
| • Conductive rubber plus polyester elastic band |
| • Contact resistance < 1 × 10⁶ Ω |
| • Continuous grounding while moving, covering the wrist strap’s blind spot |
| • Mandatory when entering ISO 7 (formerly Class 10,000) cleanrooms |
| ✓ Eliminates charging from insulating shoe soles |
| Cleanroom workbench |
|---|
| • SUS304 stainless steel frame plus epoxy powder-coated top |
| • Decay time < 0.8 seconds (IEC 61340-2-1) |
| • For use in ISO 14644-1 Class 6 cleanrooms; check the bench’s own materials and surface finish for the cleanroom class |
| • Can integrate ground cords and wrist strap test sockets |
| ✓ Table surface conductivity uniformity ±5% |
Why none of the four can be left out: the wrist strap protects grounding during seated work; the heel strap adds continuous grounding while moving — without either, there is a blind spot. The antistatic table mat deals with table surface potential, but charge has somewhere to go when the mat is connected by its conductive snap to a well-grounded workbench. The cleanroom workbench is the backbone of the whole system, deciding whether the ground path is low-impedance and stable — if the backbone is wrong, the other three are less effective.
How to combine the four: start from how the work is done
- Mainly seated work: wrist strap + antistatic table mat + well-grounded workbench form the basic ground chain.
- Work that involves walking: add heel straps to cover the wrist strap’s blind spot when moving.
- Work in a cleanroom: choose a workbench whose materials and surface finish suit the cleanroom, and confirm the range of use by cleanroom class.
- In every case: connect the mat’s conductive snap to the workbench’s ground point and the workbench to the plant grounding system; test wrist straps and heel straps for continuity regularly.
3. Results
Measured per IEC 61340-5-1 and JEDEC JESD625, after the four items were introduced: personnel static potential fell from ±280 V to ±12 V (−96%), table surface resistance from 1 × 10¹⁰ Ω to 1 × 10⁷ Ω (down three orders of magnitude), ESD events from 12 to 2 a month (−83%), and FPY rose from 96.9% to 98.6% (+1.7 percentage points).
Four measured results: item by item, with measurement conditions
Results from one customer’s production line (customer not named):
The tests covered body potential, ground resistance, table surface resistance and ambient potential monitoring; the values and measurement conditions for each are as follows:
| Indicator | Before | After | Change | Notes |
|---|---|---|---|---|
| Personnel static potential (V) | ±280 | ±12 | Down 96% | Measured at 45% relative humidity |
| Table surface resistance (Ω) | 1 × 10¹⁰ | 1 × 10⁷ | Down three orders of magnitude | Within IEC 61340 requirements |
| Static-related events (per month) | 12 | 2 | Down 83% | ICT and functional test statistics |
| First pass yield (FPY) | 96.9% | 98.6% | Up 1.7 percentage points | Judged per IPC-A-610 Class 3 |
How to read the data
- Read table surface resistance in orders of magnitude, not percentages: going from 1 × 10¹⁰ Ω to 1 × 10⁷ Ω is a change of three orders of magnitude (a factor of a thousand). Writing it as “down 99.9%” is not wrong, but badly understates it — going from 10¹⁰ to 10⁹ could also be called “down 90%,” which is a completely different improvement. For physical quantities that span orders of magnitude, such as resistance, always write “down N orders of magnitude” or give the before and after powers directly.
- Read personnel static potential together with humidity: ±280 V → ±12 V was measured at 45% relative humidity. Static dissipation changes with humidity, and readings in dry seasons are usually higher; static measurements without temperature and humidity cannot be compared with other points in time.
- Convert FPY to defect rate: 96.9% → 98.6% is a gain of 1.7 percentage points; converted to defect rate, from 3.1% to 1.4%, about 55% fewer defective units.
Where does the post-installation table resistance of 1 × 10⁷ Ω fall? ANSI/ESD S20.20 requires work surfaces to have “resistance to a groundable point of less than 1 × 10⁹ Ω,” so 1 × 10⁷ Ω passes with a good margin. The mat material’s own specification of 10⁶–10⁸ Ω falls in the static-dissipative range — not conductive — which is a deliberate choice: discharging too fast, with high instantaneous current, is worse for sensitive components.
What the 1 MΩ resistor in a wrist strap is for
A resistor is built into the wrist strap’s coil cord, and it is there for personal safety, not for static.
- Its purpose is current limiting: if the wearer accidentally touches a live conductor, this resistor limits the current through the body to below 0.5 mA. A wrist strap gives the body a low-impedance path to ground; without a current-limiting resistor, the current from an electric shock would be very dangerous.
- The standard range: ANSI/ESD S20.20 requires wrist strap systems in the range 0.8 to 1.2 × 10⁶ Ω, that is, 1 MΩ plus or minus 20%.
- When a non-standard value is used: a tailoring statement must be added to the ESD control program document explaining the reason, and the cord must be clearly marked in red with its actual resistance value.
Two common mistakes on the floor: first, replacing the cord with a low-resistance or shorted one to “ground more reliably” — this removes the current-limiting protection and is a real shock hazard; second, replacing a broken cord with ordinary wire. The cord is a safety part, not ordinary wire; when damaged, replace the whole cord with one of the same specification.
Acceptance and daily checks: keeping the results
- Check wrist straps and heel straps for continuity at a test station before entering each day: the wire inside the cord breaks from repeated bending, invisible from the outside — this is the link in the whole system that fails easily.
- Measure table resistance at several points, not just the center: the workbench’s conductivity uniformity of ±5% is worth noting — a table whose average resistance passes is not necessarily passing over the whole surface, and work placed on a spot with clearly higher resistance is effectively ungrounded. Mats also change resistance with wear, cleaner residue or surface contamination, so measure several points at acceptance and in routine checks.
- Pair heel straps with conductive or static-dissipative flooring: wrist straps work just while seated; standing and walking rely on heel straps or ESD shoes plus the floor system — the heel strap connects the person to the shoe sole, and the sole must reach a grounded floor to complete the path.
- Be clear about new and old cleanroom classes: ISO Class 6 in ISO 14644-1 corresponds to Class 1,000 in the old FED-STD-209E, one class stricter than Class 10,000 (ISO Class 7); when documents mix new and old classes, first confirm which system the other party means.
This equipment is easily treated as a one-time purchase that is “fine once installed,” but mats, wrist strap cords and heel straps are all consumables that wear out, with no visible sign when they fail; the records of regular testing are the one proof that protection is working.
4. Three often-overlooked additional benefits
| Operator comfort | Cleanliness | Maintainability |
|---|---|---|
| The new wrist and heel straps are breathable and comfortable over long shifts. Comfort directly affects whether operators actually wear them — which decides whether protection is put into practice. | The cleanroom workbench has a flat top, and the bench’s materials and surface finish are chosen for use in ISO 14644-1 Class 6 cleanrooms, reducing the chance of the bench itself becoming a source of particles. | The whole system connects modularly: wrist strap cords, heel strap elastic and mat snaps can each be replaced quickly on their own without dismantling the bench, lowering maintenance cost. |
Follow-up recommendations: set up an annual cleanliness (airborne particle) monitoring plan per ISO 14644-2, and verify the static side regularly through an ESD control program per IEC 61340-5-1; include ESD protection items in QMS audits; test wrist strap and heel strap continuity regularly; and in future, add ESD monitors and ground monitoring systems to build continuous improvement.
On SMT/EMS lines, put the four items on a check schedule
Installing the four items is just the start; a line needs measurements at fixed intervals to know the protection chain stays connected. One packaging house’s static control procedure divides check frequency into five levels, which can serve directly as the skeleton of an SMT/EMS line checklist:
| Frequency | Items checked | Acceptance (figures from the source procedure) |
|---|---|---|
| Daily | ESD shoes, wrist straps | 0.5–100 MΩ, 0.5–10 MΩ (ohmmeter) |
| Weekly | Ground connections of work areas, racks and tools | Visual |
| Monthly | Resistance to ground of conductive/dissipative work areas and floors; conductive chairs | Conductive ≤ 0.5 MΩ, dissipative 0.1–1000 MΩ, conductive chairs ≤ 10 MΩ |
| Quarterly | Ionizing fan balance and decay time; surface resistance of dissipative floor mats | Balance within ±35 V; ±1000 V down to ±100 V within 10 seconds |
| Half-yearly | Equipment grounding, power ground | Per the source procedure |
Purchase specifications for wrist straps can also serve as a reference: one wrist strap purchase specification requires a 1 MΩ current-limiting resistor built into the ground cord, a measured value of 1 MΩ ±25% for the whole cord, and a clip that can be released quickly in an emergency. Having operators test wrist straps and shoes at a test station before entering the production area each day is common practice in EMS plants; some plants tie the results to attendance so the checks are actually done.
The ESD Association’s (ESDA) ANSI/ESD S20.20 is the standard for setting up an ESD control program, formally adopted by the US Department of Defense from 2022 (adoption notice); the test method for wrist straps is ANSI/ESD S1.1 in ESDA’s list of standards (ESDA standards page).
Frequently asked questions
Q1: What ground resistance passes? It depends on the material: conductive and dissipative materials have different ranges, and a common requirement for work surfaces is less than 1 × 10⁹ Ω to the ground point (1 × 10⁷ Ω after installation in this case). For in-house checks, write the daily and monthly acceptance values clearly as in the table above.
Q2: How often should wrist straps be tested? A common practice is to test wrist straps and shoes at a test station once a day before starting work and keep the results on record; the wrist strap’s current-limiting resistor is about 1 MΩ, and if the reading is out of range, replace the band or ground cord.
Q3: How should a table mat be grounded? The mat connects through its conductive snap and ground cord to a common ground point, which connects to the plant’s ESD ground; measure table-to-ground resistance once a month to confirm the ground cord has not loosened or broken.
Want to assess the gaps in your plant’s passive protection chain?
Describe your plant’s conditions (type of work, cleanroom class, number of people), and JIAHON will help suggest a suitable four-item configuration.
▶ Contact us | Browse ESD protection products
Related articles and products: knowledge guide — “The Complete ESD Protection Guide: Is Passive Dissipation Enough, or Is Active Neutralization the Key?”; case study — “Active ESD Protection with Ionizing Fans and a Static Field Meter: An EMS Plant Case Study”; product pages — ESD workbenches (for cleanrooms); antistatic wrist straps (corded / cordless / dual-circuit).
Reference standards: IEC 61340-5-1 (ESD control programs), IEC 61340-2-1 (static decay time test), JEDEC JESD625 (handling ESD-sensitive devices), IPC-A-610 Class 3 (electronic assembly acceptability), ISO 14644-1/-2 (cleanroom classification and monitoring).
The case data in this article come from a JIAHON customer implementation report and are for reference. The solution was provided and integrated by JIAHON affiliated companies.
Related product: ESD table mats (rubber, with grounding kit) — the table surface protection among the four items in this article is this layer.
Further reading: for choosing mat material and grounding, see “How to Choose an Antistatic Table Mat”; for workbench load capacity, grounding and surface resistance, see “How to Choose an ESD Workbench.”
Standards and references
Refer to the current version published by each issuing body for the standards cited here.
- IPC-A-610, Acceptability of Electronic Assemblies. Issuer: Global Electronics Association (formerly IPC)
- IEC 61340-5-1:2024, Electrostatics – Part 5-1, Ed. 3.0. Issuer: International Electrotechnical Commission (IEC)
- ISO 14644-1:2015, Cleanrooms – Part 1, Ed. 2. Issuer: International Organization for Standardization (ISO)