Metal materials · selection guide · for R&D and purchasing
At the same 200 mesh, 316L stainless steel mesh is 0.15 mm thick while oxygen-free copper mesh is only 0.11 mm — mesh count tells only half the story.
Almost every metal mesh inquiry starts with the same sentence: “I need 200 mesh.” But mesh count only decides how dense the holes are — not how big they are, whether the mesh conducts, or whether it survives your electrolyte. Leave those three unclear, and quotes go back and forth several times. This article separates the three things you really need to confirm, with JIAHON’s actual stock specifications for five materials.
1. What is mesh count, and why isn’t it enough?
Mesh count is the number of openings per inch (25.4 mm). The higher the count, the denser and smaller the openings. The center-to-center pitch can be calculated directly: 25.4 ÷ mesh count — about 0.127 mm for 200 mesh.
But pitch is not opening size. The actual opening is the pitch minus the wire diameter; the thicker the wire, the smaller the net opening at the same count. That is why mesh count alone can’t determine filtration accuracy.
Seen in JIAHON’s own specifications: at the same 200 mesh, 316L stainless steel mesh is about 0.15 mm thick, nickel mesh about 0.13 mm and oxygen-free copper mesh about 0.11 mm. Different thickness means different wire diameter, which means these three “200 mesh” products have different net openings.
So if you are filtering or sieving, say “I need to stop particles of this size” rather than “I need this many mesh” when inquiring. With the particle size, we can work back to a combination of mesh count and wire diameter.
2. Five materials, each solving a different problem
| Material | Why choose it | Common uses | JIAHON stock mesh counts |
|---|---|---|---|
| 316L stainless steel mesh | Corrosion resistance (2–3% molybdenum; better than 304 against chloride pitting), high strength | Filtration, sieving, shielding, structural support | 20 / 40 / 60 / 100 / 200 / 250 / 300 / 400 / 500 |
| Oxygen-free copper mesh | Excellent electrical and thermal conductivity (pure copper 100% IACS) | EMI shielding, electrodes, current collectors | 20 / 50 / 100 / 150 / 200 / 250 / 300 / 400 |
| Nickel mesh | Alkali and heat resistance, stable in electrochemical environments | Alkaline battery electrodes, current collectors, catalyst supports | 60 / 100 / 150 / 200 / 250 / 300 and above |
| Titanium mesh | Resists chlorides and strongly oxidizing environments | Electrolysis, plating anodes, seawater environments | Woven 100 / 150 / 200 plus expanded diamond mesh |
| High-purity aluminium mesh | Light, low cost | Lightweight shielding, carriers, lab supports | 60 / 100 / 150 plus 0.5 × 1 mm diamond mesh |
Stock ranges only; confirm available mesh counts and wire diameters when inquiring.
Related products: metal mesh series (316L stainless steel / oxygen-free copper / nickel mesh), metal mesh series (titanium / aluminium mesh).
3. Woven vs. expanded mesh: different holes, different uses
Woven mesh interlaces metal wires over and under. The openings are regular, the mesh count precise, and it can be very fine (316L down to 500 mesh). It is used for filtration, sieving and anywhere a defined opening size is needed.
Expanded mesh (diamond openings) is a whole metal sheet slit and stretched open. It has no loose wire ends and the metal is continuous, so strength and electrical continuity are better than woven mesh, but the openings can’t be made fine. It is used for electrodes, structural parts and anywhere the whole sheet must conduct.
JIAHON’s titanium mesh comes in both: woven 100 / 150 / 200 mesh, and expanded mesh with 3 × 6 mm, 4.5 × 6 mm and 6 × 12 mm diamond openings. High-purity aluminium mesh also comes with 0.5 × 1 mm diamond openings.
In one line: precise opening size → woven mesh; whole-sheet conduction, no loose wires, use as an electrode → expanded mesh.
4. Supply form: sheet or roll?
- Width: 100 mm as standard (200 mm for 20-mesh oxygen-free copper)
- Length: 100 mm sheets or 1 m rolls
- Most nickel, titanium and aluminium mesh counts come in both lengths; 316L and oxygen-free copper come mainly in 1 m rolls.
For lab trials, 100 mm sheets are usually enough; for production lines or fixture stock, 1 m rolls are more economical. For cutting to size or punching shapes, please provide a drawing and quantity.
5. Match your need in the table
| Your need | Material | Product on our site |
|---|---|---|
| Filtration, sieving, stopping particles | 316L stainless steel mesh | Metal mesh series (stainless steel / copper / nickel) |
| EMI shielding | Oxygen-free copper mesh | Metal mesh series, pure copper foil |
| Alkaline battery electrodes, current collectors | Nickel mesh | Metal mesh series, metal foam (nickel / copper) |
| Electrolysis, plating anodes, seawater | Titanium mesh (expanded) | Metal mesh series (titanium / aluminium) |
| Lightweight supports, lab carriers | High-purity aluminium mesh | Metal mesh series (titanium / aluminium), metal foam (titanium / iron / aluminium / silver) |
| Current collectors needing very high specific surface area | Metal foam (not mesh) | Nickel foam / copper foam |
| Insect and dust screens for buildings | 304 stainless steel window screen | 304 stainless steel window screen (a separate product line) |
6. FAQ
Is a higher mesh count always better? No. A higher count means finer openings and better filtration accuracy, but lower flow, more clogging and higher cost. Choosing a mesh count balances what you need to stop against how much flow you need to pass; finer is not automatically better.
What is the difference between 304 and 316L? Do I need 316L? Molybdenum. 316L contains 2–3% molybdenum (16–18% chromium, 10–14% nickel), giving better resistance than 304 to chloride pitting and to reducing acids such as sulfuric acid; the L means low carbon, which reduces sensitization after welding. The rule is simple: with chlorides (seawater, chlorinated cleaners, electrolytes) or acids, choose 316L; in ordinary dry or neutral environments, 304 is enough. Related products: 316L stainless steel mesh, stainless steel wire.
Can it be cut to my size? Yes. Stock is 100 mm wide in 100 mm sheets or 1 m rolls; for a specified width, length or punched shape, please provide a drawing and quantity. Fine meshes tend to fray at cut edges, so mention any edge requirements.
Should a current collector use metal mesh or metal foam? It depends on whether you need mechanical strength or specific surface area. Mesh is two-dimensional — easy to cut and fix, with uniform thickness; foam is a three-dimensional porous structure with much higher specific surface area and porosity, allowing more active material loading, but it is more fragile and needs care when cutting. A common approach in electrochemical research is to try both: confirm the electrode reaction with mesh, then raise loading with foam. Related products: metal foam (nickel / copper, 40 μm pores), metal foam (titanium / iron / aluminium / silver).
Is window screen the same as the metal mesh here? No, it’s a different product line. This page covers woven and expanded metal mesh for lab and industrial use, selected by mesh count and material; building insect and dust screens are a separate item specified mainly by roll width and mesh density, with different uses and acceptance methods. Related product: 304 stainless steel window screen.
Give us the use, the particle size to stop or the electrode area, the working environment (chlorides, acids or alkalis, temperature) and the quantity, and we can help work out the mesh count and material. Small quantities for research and trials are welcome. Please contact JIAHON or email [email protected].