中文

ESD wrist straps for cleanrooms

Five types, from wireless bands to dual-wire wrist straps.

Wired or wireless: the grounding method sets the protection level

A wired strap continuously drains body static through a ground cord to a ground point. With a good ground, it is the most reliable method recognized in ANSI/ESD S1.1. A wireless (cordless) strap uses built-in capacitive or resistive elements for local static suppression; it is easier to move around with but gives weaker protection than a wired strap. For highly sensitive parts (bare die, BGAs, precision sensors), use a wired strap; consider a wireless strap only where grounding is not possible or operators move around often.

The five types

TypeGroundingCord / featuresWeightWhere used
Adjustable oval wireless bandWireless (built-in)Standard, no cord, adjustable oval design25 gWhere grounding is not possible / line patrol staff
Wired strap, 1.8 mWired1.8 m ground cord for fixed benches—Bench work with little movement
Wired strap, 4 mWired4 m extended ground cord, wider reachBand 8 g, total 40 gStations that need some movement, SMT lines
Dual-wire wrist strapWired, two circuitsTwo independent ground circuits; protection continues if one breaks—High-risk work, continuous monitoring
ESD ankle strap (black / blue)Wired (ankle)Worn with ESD shoes on ESD flooring—Assembly work where both hands must be free

Why dual-wire

A standard wired strap has one ground circuit. If the band loosens, the cord breaks or the ground point fails, body static can build up without the operator noticing. A dual-wire design runs two independent circuits at the same time; if one opens, the other keeps protecting, and it can be used with a continuous monitor that raises an alarm. It is used at workstations handling very static-sensitive parts such as wafers and MEMS sensors.

Request a quote

Tell us the types, cord lengths and quantity. Availability and price are confirmed in our reply. Request a quote →

Back to top