KEYENCE AP-C30W Compound Pressure Sensor | Vacuum and Positive Pressure, −101.3 to +100 kPa

JIAHON is not the authorized distributor of KEYENCE in Taiwan.

KEYENCE AP-C30W compound pressure sensor

The KEYENCE AP-C30W is a compound digital pressure sensor covering −101.3 kPa (vacuum) to +100.0 kPa (positive pressure), so a single unit can monitor both states in a pneumatic circuit. It has a digital display for real-time readings and two NPN open-collector outputs (OUT1 / OUT2) that connect directly to a PLC for process pressure interlocks. Key selection points: pressure range, output type (NPN / PNP) and wiring type.

AP-C series models

ModelPressure typeRangeOutputDisplay
AP-C30Compound−101.3 to +100.0 kPaNPN open collector3-digit LCD
AP-C30WCompound−101.3 to +100.0 kPaNPN open collector (cable type)3-digit LCD
AP-C33Compound−101.3 to +100.0 kPaPNP open collector3-digit LCD
AP-C33WCompound−101.3 to +100.0 kPaPNP open collector (cable type)3-digit LCD

The AP-C30 series is compound (vacuum + positive pressure); the AP-C40 series is for positive pressure only.

NPN or PNP? It depends on the PLC input module: Japanese PLCs commonly use NPN (sink) inputs, European PLCs commonly use PNP (source) inputs. Check the wiring of your PLC digital input module before choosing.

Specifications

ItemDetails
Pressure typeCompound (vacuum + positive pressure)
Measuring range−101.3 to +100.0 kPa
Applicable fluidAir, non-corrosive gases
Power supply12–24 VDC (ripple 10% incl.)
Output2 × NPN open collector (OUT1 / OUT2)
Max. load current80 mA
Repeatability±0.2% F.S.
Response time2.5 / 5 / 100 / 500 / 1000 ms selectable
PortR1/8 (PT 1/8)
ProtectionIP40
Operating temperature0 to +50°C
Housing materialPBT

Typical applications

ApplicationPurposeSetting reference
Placement machine vacuum nozzlesConfirm sufficient vacuum to prevent dropped partsVacuum side −40 to −80 kPa
Pneumatic grippers / cylindersConfirm normal supply pressurePositive side +40 to +60 kPa
Test fixture leak checksMonitor pressure change from leaksPer fixture design
Equipment compressed airLow-pressure alarm interlockLow limit on positive side

One sensor, two set points: with a compound sensor, OUT1 can watch the vacuum side and OUT2 the positive side. For example, on a nozzle circuit OUT1 alarms when vacuum is weaker than −50 kPa (insufficient suction) and OUT2 confirms vacuum break when pressure exceeds +20 kPa.

Quick selection

StepCheckChoice
1. Pressure typeVacuum needed, or positive pressure only?Vacuum + positive → AP-C30 series; positive only → AP-C40 series
2. OutputPLC input NPN (sink) or PNP (source)?NPN → AP-C30 / C30W; PNP → AP-C33 / C33W
3. WiringConnector or cable?Connector → AP-C30; cable → AP-C30W

When requesting a quote, please tell us: compound or positive-pressure type, NPN or PNP, and quantity. If you have the existing model number (e.g. AP-C30W), include it.