KEYENCE AP-C30W compound pressure sensor
The KEYENCE AP-C30W is a compound digital pressure sensor covering −101.3 kPa (vacuum) to +100.0 kPa (positive pressure), so a single unit can monitor both states in a pneumatic circuit. It has a digital display for real-time readings and two NPN open-collector outputs (OUT1 / OUT2) that connect directly to a PLC for process pressure interlocks. Key selection points: pressure range, output type (NPN / PNP) and wiring type.
AP-C series models
| Model | Pressure type | Range | Output | Display |
|---|---|---|---|---|
| AP-C30 | Compound | −101.3 to +100.0 kPa | NPN open collector | 3-digit LCD |
| AP-C30W | Compound | −101.3 to +100.0 kPa | NPN open collector (cable type) | 3-digit LCD |
| AP-C33 | Compound | −101.3 to +100.0 kPa | PNP open collector | 3-digit LCD |
| AP-C33W | Compound | −101.3 to +100.0 kPa | PNP open collector (cable type) | 3-digit LCD |
The AP-C30 series is compound (vacuum + positive pressure); the AP-C40 series is for positive pressure only.
NPN or PNP? It depends on the PLC input module: Japanese PLCs commonly use NPN (sink) inputs, European PLCs commonly use PNP (source) inputs. Check the wiring of your PLC digital input module before choosing.
Specifications
| Item | Details |
|---|---|
| Pressure type | Compound (vacuum + positive pressure) |
| Measuring range | −101.3 to +100.0 kPa |
| Applicable fluid | Air, non-corrosive gases |
| Power supply | 12–24 VDC (ripple 10% incl.) |
| Output | 2 × NPN open collector (OUT1 / OUT2) |
| Max. load current | 80 mA |
| Repeatability | ±0.2% F.S. |
| Response time | 2.5 / 5 / 100 / 500 / 1000 ms selectable |
| Port | R1/8 (PT 1/8) |
| Protection | IP40 |
| Operating temperature | 0 to +50°C |
| Housing material | PBT |
Typical applications
| Application | Purpose | Setting reference |
|---|---|---|
| Placement machine vacuum nozzles | Confirm sufficient vacuum to prevent dropped parts | Vacuum side −40 to −80 kPa |
| Pneumatic grippers / cylinders | Confirm normal supply pressure | Positive side +40 to +60 kPa |
| Test fixture leak checks | Monitor pressure change from leaks | Per fixture design |
| Equipment compressed air | Low-pressure alarm interlock | Low limit on positive side |
One sensor, two set points: with a compound sensor, OUT1 can watch the vacuum side and OUT2 the positive side. For example, on a nozzle circuit OUT1 alarms when vacuum is weaker than −50 kPa (insufficient suction) and OUT2 confirms vacuum break when pressure exceeds +20 kPa.
Quick selection
| Step | Check | Choice |
|---|---|---|
| 1. Pressure type | Vacuum needed, or positive pressure only? | Vacuum + positive → AP-C30 series; positive only → AP-C40 series |
| 2. Output | PLC input NPN (sink) or PNP (source)? | NPN → AP-C30 / C30W; PNP → AP-C33 / C33W |
| 3. Wiring | Connector or cable? | Connector → AP-C30; cable → AP-C30W |
When requesting a quote, please tell us: compound or positive-pressure type, NPN or PNP, and quantity. If you have the existing model number (e.g. AP-C30W), include it.
Related: Panasonic DP-101 vacuum pressure sensors · MKS 626B vacuum pressure sensor · SMC ISE20A / ZSE pressure switches