KEYENCE FD-XS8 Clamp-On Ultrasonic Flow Sensor Head | ø6 mm (1/4″) Tube, 0–3,000 mL/min

JIAHON is not the authorized distributor of KEYENCE in Taiwan.

KEYENCE FD-XS8 clamp-on ultrasonic flow sensor head

Conventional flow meters need the pipe to be cut and the line stopped for installation, which costs downtime and adds leak risk. The FD-XS8 uses transit-time ultrasonic measurement: the sensor head clamps onto the outside of the tube, with no pipe cutting and no wetted parts, so it can be installed while the process keeps running. It fits resin or metal tubes with ø6 mm (1/4″) outer diameter, measures 0–3,000 mL/min and reaches ±0.1% FS accuracy at 50 ms response on resin tubes.

The difference in ultrasonic transit time between the downstream and upstream directions is proportional to flow velocity.

Specifications

ItemDetails
ModelFD-XS8 (8 L/min sensor head; requires an FD series controller)
Applicable tubeOuter diameter ø6 mm or 1/4″ (resin / metal tube)
Rated flow0–3,000 mL/min (ø6 / 1/4″ tube); low-flow cutoff 40 mL/min
Accuracy (resin tube)50 ms response: ±0.1% FS; 500 ms response: ±1.0 mL/min
Accuracy (metal tube)50 ms response: ±0.3% FS; 500 ms response: ±2.9 mL/min
Fluid temperature0–100°C (no freezing on tube surface)
ProtectionIP65 / IP67 / IP68G
Ambient temperature−10 to +60°C (no freezing)
MaterialsSensor: PPS / PPSU; bracket: PPS + special rubber + SUS XM7 screws
WeightApprox. 250 g (with bracket)

Transit-time vs. Doppler

Ultrasonic flow meters come in two types. Transit-time meters are for clear liquids (cooling water, ultrapure water, chemicals), since the ultrasound must pass fully through the liquid. Doppler meters are for liquids containing suspended particles or bubbles, relying on reflections from those particles. The FD-XS8 is a transit-time type, suited to semiconductor process cooling water and chemical flow monitoring.

  • Install without shutdown: the head clamps onto the tube with a bracket, so it can be installed or replaced while the process runs.
  • 50 ms response: for fast flow-abnormality detection or closed-loop flow control.

Note: the FD-XS8 is a sensor head only and must be used with a KEYENCE FD series controller; please confirm the controller model separately.