KEYENCE GT2-71MCN Amplifier Unit | GT2 Series, NPN 5-Level Judgment, 4–20 mA Analog Output

JIAHON is not the authorized distributor of KEYENCE in Taiwan.

KEYENCE GT2-71MCN amplifier unit

The KEYENCE GT2-71MCN is the NPN analog-output main unit of the GT2 series. It has a 6½-digit LED display (0.1 μm resolution), a 4–20 mA analog output (350 Ω max. load) and NPN open-collector 5-level judgment outputs (HH / HI / GO / LO / LL). It mounts on a DIN rail, offers selectable response from 3 ms, and has an IP67 front panel — for precision dimensional quality control and automatic in-line thickness / height judgment.

Specifications

ItemGT2-71MCN
Model / typeGT2-71MCN / NPN analog-output main unit
MountingDIN rail
Power supply20–30 VDC, ripple ±10% (Class 2)
Power consumptionStandard ≤2,700 mW (30 V / 90 mA); eco mode ≤2,200 mW (73.3 mA)
Display6½-digit red 7-segment LED (−199,999.9 to +199,999.9); 0.1 μm resolution; two-color 13-segment bar LED
Control (judgment) outputNPN open collector, 5 levels (HH / HI / GO / LO / LL); max. 40 V / 50 mA; residual voltage ≤1 V
Analog output4–20 mA; max. load resistance 350 Ω
Response timehsp (3 ms) / 5 / 10 / 100 / 500 / 1000 ms selectable
Operating environment−10 to +50°C (+45°C with expansion units); 35–85% RH
Front panel protectionIP67
WeightApprox. 70 g (polycarbonate housing)

Outputs

OutputSpecificationTypical use
4–20 mA analogProportional to measured displacement, max. load 350 ΩTo PLC analog input, recorder or DCS for trend monitoring and SPC
NPN 5-level judgment (HH / HI / GO / LO / LL)Adjustable thresholds, NPN open collector 50 mAPLC digital input receives GO / NG to drive alarms or reject defective parts
Two-color bar LED13-segment green / red displayOperators see at a glance whether the value is within tolerance

GT2 system configuration

  • Main unit (GT2-71MCN): this product — processes the GT2 sensor signal, displays the value and outputs analog and judgment signals.
  • Sensor head (GT2-H series): contact displacement sensor head, sold separately; choose by measuring range and accuracy.
  • Expansion units: the GT2-71MCN supports side-by-side expansion to manage multiple measuring channels (operating temperature limit drops to +45°C).
  • Response: hsp (3 ms) for high-speed lines; 100 ms for stable measuring conditions.

Related: SICK GTB6 / GL6 / GSE6 photoelectric sensors (G6 series) · FLIR T540 / C8 thermal imaging cameras