中文

SL-031A Wrist Strap and Footwear ESD Tester | LO / PASS / HI, Gate Interlock, EPA Entry Control

Daily ESD check at the EPA entrance

The SL-031A is designed for checking personnel before they start work in an EPA (ESD protected area). One unit tests the anti-static wrist strap and the left and right ESD shoes, with three test modes that can be combined as needed. Results are shown as LO / PASS / HI with LED indicators and a buzzer; a fail triggers a continuous alarm to alert supervisors. The output signal can be linked to an entry gate so that anyone who fails the test cannot enter, supporting ESD audits and ISO controls in SMT and semiconductor plants.

Specifications

ItemSpecification
ModelSL-031A
Wrist strap range750 kΩ – 10 MΩ
ESD shoe range750 kΩ – 100 MΩ (left / right independent)
Accuracy±10%
PowerPower adapter (AC 220 V input / 9 V DC output)
Foot plate size420 × 400 × 35 mm (H)
Unit size165 × 96 × 44 mm (H)
Total weight6.5 kg
MountingFloor-standing (adjustable stand height) / wall-mounted

Features

  • Three tests in one: wrist strap + left shoe + right shoe in a single sequence, shortening the daily pre-shift check.
  • Three-level result: LO / PASS / HI with LED indicators and buzzer; continuous alarm on failure.
  • Gate interlock: the output signal can link to an access gate so that failed personnel cannot enter the controlled area.
  • Flexible mounting: floor-standing with adjustable stand height, or wall-mounted, to suit different entrance layouts.

Applications

  • EPA entrances
  • Daily pre-shift checks on SMT lines
  • ESD control in semiconductor plants
  • ISO / IEC ESD audits

Related: JIAHON JH-F130 ionizing fan · JHKL-10 multi-channel ground monitor alarm · Cleanroom wrist straps

Contact us for a quote or to confirm a specification via our Request a quote page