JIAHON is not the authorized distributor of SMC in Taiwan.
SMC ITV2050-042BL electro-pneumatic regulator
The ITV series electro-pneumatic regulator converts a current or voltage signal from a PLC into an accurate air pressure output, giving stepless pressure adjustment. It is a core component for precision pressure control on automated production lines.
What an electro-pneumatic regulator does
A manual regulator holds one fixed pressure set by its knob and cannot change it during a process. An electro-pneumatic regulator receives an analog signal from the PLC (current or voltage type) and converts it linearly into a matching output pressure — for example, the minimum signal gives the minimum pressure and the maximum signal gives the set upper pressure — so the PLC can change pressure precisely during the process.
Specifications
| Item | Details |
|---|---|
| Model | ITV2050-042BL |
| Series | SMC ITV2000 |
| Pressure range | 0.005–0.9 MPa |
| Port size | Rc 1/4″ |
| Power supply | DC 24 V |
| Response time | Approx. 0.1 s |
| Repeatability | ±0.5% F.S. |
| Protection | IP65 |
| Pressure display | LED digital display (MPa) |
ITV series sizes
| Series | Port | Pressure range | Use |
|---|---|---|---|
| ITV1000 | 1/8″ | 0.001–0.9 MPa | Small precision equipment |
| ITV2000 | 1/4″ | 0.005–0.9 MPa | General production lines (this product) |
| ITV3000 | 3/8″ | 0.005–0.9 MPa | High-flow processes |
Selection note: ITV models are available for current-type and voltage-type input signals. Check the specification of your PLC analog output module before ordering, and confirm the input signal type of this model with us. This is general guidance; please confirm for your application.
Maintenance tips
- After power-on, the keys are locked and any key press shows “Loc”. To change settings, hold the DOWN key for more than 2 seconds; when “Loc” flashes, press SET to unlock.
- “Er” followed by a number indicates an error: Er1 input signal out of range, Er2 EEPROM read/write, Er3 memory read/write, Er4 solenoid valve failure, Er5 switch output overcurrent. Switch off the power, find and remove the cause, then power on again.
- To reset the settings, hold the UP and DOWN keys together for more than 3 seconds and release when “RES” is displayed.
- Filter the air supply to 5 μm. If lubrication is needed, install the lubricator on the outlet side of this valve, not the inlet side.
- The valve is adjusted at the factory; do not disassemble it.
- If supply pressure is lost while power is still on, the solenoid valve will keep chattering — switch off the power. Fully insulate the ends of unused monitor-output wires. Maximum cable length is 10 m.