SMC SY7000 series solenoid valves
The SY7000 series is SMC’s 5-port solenoid valve range for directional control of cylinders on automated equipment. The models below are those we commonly handle; for other models, email us with the full model number.
SY7120 series
| Models | | |
|---|
| SY7120-5D-02 | SY7120-5DD-02 | SY7120-5DZD-02 |
| SY7120-5DZ-02 | SY7120-5DE-02 | SY7120-5DZD-C8 |
| SY7120-5DZ-C8 | SY7120-5DD-C8 | SY7120-5DZ-C10 |
| SY7120-5DZD-C10 | SY7120-4D-02 | SY7120-4DZ-02 |
| SY7120-4DD-02 | SY7120-4DZD-02 | SY7120-3DZ-02 (AC110V) |
| SY7120-5YO-02F-Q | SY7120-5DOSD-02-F2 | SY7120-5DZD-02-DNW9936 |
SY7220 series
| Models | | |
|---|
| SY7220-5DZD-02 | SY7220-5DZ-02 | SY7220-5DD-02 |
| SY7220-5D-02 | SY7220-3D-02 | SY7220-3DZ-02 |
| SY7220-3DZD-02 | SY7220-4D-02 | SY7220-4DZ-02 |
| SY7220-4DZD-02 | SY7220-4DD-02 (AC220V) | SY7220-5D-C10 |
| SY7220-5DZ-C8 | SY7220-5DD-C8 | SY7220-5DZ-C10 |
| SY7220-5DZD-C10 | | |
SY7320 series
| Models | | |
|---|
| SY7320-5D-02 | SY7320-5DD-02 | SY7320-5DZ-02 |
| SY7320-5DZD-02 | SY7320-4DZD-02 | SY7320-5DD-C8 |
| SY7320-5DZ-C8 | SY7320-5DZD-C8 | SY7320-5DD-C10 |
| SY7320-5DZ-C10 | SY7320-5DZD-C10 | SY7320-5DSD-C8 |
| SY7320-3DZ-C8 | | |
SY7420 / SY7520 series
| Models | | |
|---|
| SY7420-5DZ-02 | SY7420-5DD-02 | SY7420-5D-02 |
| SY7420-5DZD-02 | SY7420-4D-02 | SY7520-5DZ-02 |
Maintenance tips
- Install an air filter with a filtration rating of 5 μm or finer close to the valve on the upstream side, and drain the water from the filter bowl regularly.
- Rubber-seal types are lubricated for life at the factory and need no oiling. However, once lubrication of the system has started, it must be continued, using only ISO VG32 Class 1 turbine oil (no additives); other oils may cause malfunction.
- Too much oil collects in the pilot valve and can make operation slow or stop it; oil should not spray from the exhaust port (E).
- Pressing the manual override moves the connected cylinder, so check the surroundings first. For the push-and-turn locking type, push fully before turning — turning it without pushing will damage it and cause leakage. Do not apply excessive turning force.
- Operate the valve at least once every 30 days; valves left unused for long periods tend to stick.
- When several adjacent stations are energized at the same time for long periods, the coils heat up noticeably and their life is shortened; for this use, choose a type with a power-saving circuit.