中文English

SMT Nozzle Cleaning and Maintenance: How Often to Clean, How to Read the Dump Rate, Lubrication and Valve Replacement

A placement machine’s accuracy does not depend only on the controller and software; much of the time, it is lost on basic cleaning and lubrication

Jiahon Group Engineering Team · About 5 minutes to read

When it comes to placement machines, most people think first of the controller and software. But on the actual line, the long-term stability of mounting often depends on three basic things: the cleanliness of the nozzles, the lubrication of moving parts, and the sealing of the vacuum system. None of these are “fix it when it breaks” items; they are engineering work that can be built into a maintenance plan.

How Should Nozzles Be Maintained So You Don’t “Use Them Until They Break”?

Upgrading nozzle maintenance from manual work to a standardized, automated process is not about saving labor; it is about keeping every nozzle close to the condition of a new machine from the OEM throughout its reasonable life, and building a predictable life curve so spares can be prepared and replaced in a planned way ahead of time. Jiahon’s fully automatic nozzle cleaning machines come in three positions:

ModelPositionEquipment dimensionsCore functions
JHPBT-40Cleaning600×550×640mmHigh-pressure water mist impact cleaning, 40 nozzles at a time, in groups of 4
JHPBT-60SCleaning + inspection1450×900×1650mmUltrasonic cleaning + CCD vision inspection, X/Y/Z three axes
JHPBT-80Four-in-one full function1150×1200×1900mmCleaning + vacuum testing + sorting + 2D barcode recognition

See Fully Automatic Nozzle Cleaning Machines JHPBT-40 / 60S / 80 ›

When Nozzles Get Dirty, Look at the Dump Rate First: Cleaning Frequency and Practices on the Line

The nozzle is the part of the placement machine that most often comes into contact with solder paste, flux, and dust. Contamination or wear shows up first in the dump rate (the proportion of components discarded because of pick failures or recognition failures). In the engineering data, one placement machine acceptance report measured a 0402 dump rate of 0.555% (8 / 1,440) and 0201 at 0.694% (3 / 720) at acceptance — recording the dump rate at the time of acceptance gives you a baseline for “how much worse it has gotten” later.

  • Daily: check each nozzle. One placement machine maintenance specification’s practice is to use the machine’s nozzle check function (Check nozzle) to check each nozzle one by one; for abnormal ones, first apply a small amount of lubricating oil and retest, repeating up to 3 times, and if it still fails, hand it over to engineering.

  • Solder on the nozzle: clean in order. The same specification requires that a nozzle with solder on it be cleaned in order by blowing with an air gun, clearing the hole with fine steel wire, and removing with tape, repeated for 3 rounds; the spline shaft is flushed with IPA until the IPA flowing out runs clear.

  • Periodically: put it on the equipment maintenance schedule. One SMT equipment maintenance item list puts “cleaning inside and outside the nozzle holder, nozzle cleaning, and the transfer head filter” for the placement machine into weekly/monthly maintenance; if the vacuum filter is less than 1/3 dirty, blow it with an air gun, and if more than 2/3, replace it.

  • If the dump rate suddenly rises, first rule out causes other than the nozzle. One study of an out-of-spec dump rate found the true cause was not the nozzle but plastic carrier tape used with the wrong feeder and a mismatched feed quantity; so when the dump rate rises, first see whether it is concentrated on one nozzle, or on one part number or feeder.

Manual cleaning tends to vary from person to person; on lines with high volumes or many small nozzles (0201, 01005), switch to a fully automatic nozzle cleaning machine, so cleaning conditions are fixed and records can be kept; for manual cleaning, use cleanroom wipes with IPA to avoid leaving fibers in the nozzle hole.

How to Choose the Right Lubricant Part Number

Lubrication is a hidden key to placement machine stability, but different mechanism positions call for different part numbers; one bottle does not fit all. Three part numbers common on Panasonic placement machines are N510048190AA, KXF05PLAA00, and N510059330AA; confirm the actual position of use against the machine’s maintenance manual, and if unsure, tell Jiahon the machine model and maintenance position, and our engineers can help match the part number.

See Panasonic Placement Machine Lubricant Series ›

› Related products: Lubrication and Maintenance Spares Compatible with Yamaha

When Should the Vacuum Valve Be Replaced?

The valve is a hidden part that supports long-term stable operation; wear is gradual and usually does not stop the machine outright, but shows up first as a higher pick error rate. Common symptoms and corresponding actions:

SymptomPossible root causeRecommended action
Nozzle pick error rate risingWear on the valve sealing surface, vacuum leakReplace the valve, then retest the vacuum value
Vacuum gauge reading lowValve aging or foreign matter caught on the sealing surfaceClean first; replace if there is no improvement
Scheduled preventive maintenanceReplace parts on the machine’s maintenance plan cycleRecommended to replace together with the nozzles, all in one go

Applicable part numbers N413MDV2-079 and 234-RL7C, compatible with Panasonic CM402 / CM602. See Mechanical Valve 2VB Head Vacuum Valve ›
› Related products: Vacuum Valve and Solenoid Valve Spares Compatible with Yamaha, Filters, Nozzle Shafts, and Vacuum Spares Compatible with FUJI

Not sure where to start building a maintenance plan for your machines? Tell Jiahon your machine models and current pick error situation, and our engineers can help take stock of your spares list across the three areas: nozzles, lubrication, and vacuum.

Frequently Asked Questions

Q1: How often should nozzles be cleaned?

It depends on volume and the degree of contamination. A common practice is to check each nozzle before the line starts every day, clean any with solder on them, and put nozzle and nozzle holder cleaning into weekly or monthly maintenance; the actual frequency follows the equipment maker’s maintenance manual.

Q2: What dump rate counts as normal?

There is no general standard; it depends on component size, carrier tape, and machine model. We recommend measuring once for each component size at new machine acceptance or after maintenance as a baseline, then comparing against that baseline; IPC lists placement equipment throughput and accuracy as standard measurement items in IPC-9850A (characterization of surface mount placement equipment) (table of contents), which can serve as a method for comparison at acceptance and after maintenance; the SMT trade journal Circuits Assembly also notes that the point of this standard is to compare different machines using a consistent measurement procedure (article).

Q3: Can nozzles be cleaned ultrasonically?

Yes, but confirm that the nozzle material and reflector can withstand it, and avoid nozzles of different sizes knocking against each other; where a dedicated nozzle cleaning machine is available, use the cleaning method the equipment maker recommends first.

Back to top