Components such as ICs and connectors that have been stored too long can crack when they go into the reflow oven — what the industry calls the “popcorn effect”. The cause is not a defective component; it is absorbed moisture: the high temperature of reflow vaporizes the moisture inside the package, which expands and forces the package apart. JEDEC standardized this with MSL (Moisture Sensitivity Level), and the packaging and storage rules are written in J-STD-033. This article explains three things from a purchasing and warehouse point of view: how to read the level, what the packaging needs, and how to count time after opening.
1. What the MSL level controls: “floor life” after opening
The MSL level is not a quality score, but a grading of how long a component can stay in a normal factory environment after its pack is opened (known in the industry as floor life). The higher the level number, the more sensitive to moisture it is, and the shorter the time it can be exposed. So for the same batch of material, the MSL level decides the rhythm of your line: whether you can open it all at once, how soon after opening it must go on the line, and what to do with what is left unused.
In practice, note that floor life is cumulative; it does not restart each time the pack is opened. Opened for two hours and put back, then opened for three hours the next day, the cumulative total is five hours. This is why the warehouse must record the opening time and cumulative hours on the bag — relying on memory is bound to go wrong.
2. The four things a standard pack should have
The dry pack specified by J-STD-033 is not as simple as “putting it in a bag”; without any one item, traceability is lost:
| Item | Purpose | What happens without it |
|---|---|---|
| Moisture barrier bag (MBB) | Blocks moisture and UV; can be vacuumed and heat-sealed | Moisture gets straight in, and even a low level cannot keep it out |
| Desiccant | Absorbs residual moisture inside the bag | The humidity from sealing stays inside and is slowly absorbed by the components |
| Humidity indicator card (HIC) | On opening, shows whether the pack was exposed to moisture during transport and storage | You cannot tell whether baking is needed and can just guess |
| MSL label | States the level, the seal date and the floor life limit | The floor does not know how long this batch can be left out |
The protection of the aluminum foil bag comes from a multi-layer laminate: the outer PET layer resists tearing, the middle aluminum foil blocks moisture and gases, and the inner anti-static PE provides ESD protection — each of the three layers has its function, and without one, overall protection drops. For electronic components and ICs, always choose the anti-static type (surface resistance 10⁶–10⁹ Ω, triboelectric voltage below 50 V); the ordinary type is suitable just for food and chemicals. Jiahon’s anti-static aluminum foil bags have an open-top heat-seal design that works directly with heat sealers or vacuum sealers, thickness 0.12–0.15 mm, puncture resistance 80–140 N, with custom sizes and printing (lot number, warning text, part number).
3. How to read a humidity indicator card
The humidity indicator card is placed inside the bag, and on opening its color tells you whether anything went wrong during transport and storage. The six-spot humidity indicator card uses blue for dry and pink for exposed to moisture; one card shows six humidity levels at the same time, and reading it is intuitive:
All six spots blue: the environment is dry; use normally within the floor life of the MSL level.
Any spot turned pink: there are signs of moisture inside the pack; check the condition of the components first, then decide whether baking is needed — do not put them straight on the line.
The card is reversible: its color recovers after drying in a dry cabinet (lead-free, RoHS compliant); but if the 60% spot has changed color, it means it was exposed to high humidity, and according to J-STD-033D this card cannot be reused in moisture barrier packaging and must be replaced with a new card.
Note: the indicator card tells you about “the environment inside the bag”, not “the moisture content inside the components”. It is the first basis for judgment, not the final word.
4. What to do when floor life is exceeded: dry storage and baking
Two routes: material that has not exceeded its time is kept in a low-humidity environment: MSL 2–3 stored below 10% RH can pause the count; MSL 4–5a opened for no more than 8 hours must be stored below 5% RH for 10 times the exposure time before the clock can be reset, and beyond 8 hours it must be baked; material that has exceeded its time, or whose indicator card has changed color, must be baked according to the standard to drive out the moisture, and then the clock is reset. Baking conditions and time depend on the package type and the heat resistance of the carrier — whether the trays withstand high temperature and whether a whole tray can go into the oven is a limit that is easy to trip over in practice.
For low-humidity storage, watch for “a difference in grade”: ordinary consumer dry cabinets reach just 30–60% RH, which means nothing for moisture-sensitive components. For industrial use, choose a model with active dehumidification that can really get below 10% RH. Jiahon’s SXC series ultra-low humidity electronic dry cabinets come in two grades, 1%–10% RH (general precision electronics storage) and 1%–3% RH (very low humidity requirements), in five capacities from SXC-100 (450×400×700 mm) to SXC-1450 (1200×700×1890 mm), with humidity control by an ARM chip, a temperature and humidity sensor, and an ESD powder-coated cabinet (static resistance 10⁶–10⁹ Ω). The two grades of the same model have exactly the same outer dimensions, number of shelves and power consumption; the difference is just the precision of the dehumidifying module — choose by the humidity requirement of the stored material, with no need to compromise on size.
5. Four practical actions for the warehouse and purchasing
| When | What to do |
|---|---|
| Receiving | Check that the foil bag is intact, the indicator card is all blue, and the MSL label is complete |
| Opening | Record the opening time on the bag and in the system, and start counting cumulative exposure hours |
| Not used up | Put it back in a low-humidity environment (dry cabinet) the same day: MSL 2–3 can pause the count, MSL 4–5a is handled under the J-STD-033 conditions; do not leave it on the line |
| Abnormal | If the indicator card has changed color or the time is exceeded, quarantine it first, bake according to the standard and reset the clock; do not force it onto the line |
Frequently asked questions
Does a higher MSL level mean poorer quality?
No. The level reflects how sensitive the package is to moisture and has nothing to do with whether the component is good or bad; what it decides is your storage and line rhythm.
If the humidity indicator card changes color, must it be baked?
Not necessarily, but it cannot be ignored. The indicator card shows that the environment inside the bag was exposed to moisture; quarantine and check the condition of the components first, then decide according to the standard whether to bake.
Can an ordinary dry cabinet be used to store moisture-sensitive components?
Not recommended. Consumer dry cabinets are mostly at 30–60% RH; moisture-sensitive components need an industrial active-dehumidification model that can hold steadily below 10% RH.
Where can I look up the related soldering standards?
For process requirements see “J-STD-001 Guide“, and for acceptance judgment see IPC-A-610; for how the two divide the work, see “J-STD-001 vs IPC-A-610“.
If you need to plan the consumables for dry packing (foil bag specifications, monthly indicator card use, dry cabinet capacity), you are welcome to contact Jiahon; our technical sales staff can help configure them according to your parts and line rhythm.
Further reading: How to Choose an ESD Bag? Anti-Static, Conductive and Shielding — the Differences, and When a Foil Bag Is a Must
Further reading: PCBA Moisture Barrier Packaging: 4 Situations That Need It, and How to Match the Foil Bag
Further reading: PCB Baking: Should Expired Boards Be Baked? A 4-Step Decision Process
Further reading: Storage and Baking Conditions for Moisture-Sensitive Components: How to Handle the 4 States After Opening
Further reading: Tray vs Tape and Reel: 8 Comparisons, and How BGAs and QFPs Go on the Line and Are Stored
Further reading: Dry Cabinet vs Nitrogen Cabinet: 4 Selection Points for Storing Moisture-Sensitive Items in Electronics Plants
Further reading: What Is the Popcorn Effect: Why Moisture-Laden ICs and Boards Crack in the Reflow Oven
Standards referenced
For the standards cited in this article, please follow the current revision from each publishing body.
IPC/JEDEC J-STD-033 “Handling, Packing, Shipping and Use of Moisture, Reflow, and Process Sensitive Devices”
Publisher: Global Electronics Association (formerly IPC) and JEDECIPC/JEDEC J-STD-020 “Moisture/Reflow Sensitivity Classification for Nonhermetic Surface Mount Devices”
Publisher: Global Electronics Association (formerly IPC) and JEDECIPC-A-610 “Acceptability of Electronic Assemblies”
Publisher: Global Electronics Association (formerly IPC)IPC J-STD-001 “Requirements for Soldered Electrical and Electronic Assemblies”
Publisher: Global Electronics Association (formerly IPC)RoHS Directive 2011/65/EU “Restriction of Hazardous Substances in EEE”
Publisher: European Commission