ABB Circuit Breakers | Tmax XT1N160 MCCB / S201-B10 MCB

JIAHON is not the authorized distributor of ABB in Taiwan.

ABB circuit breakers | Tmax XT1N / S200 series, 36 kA molded case and miniature

XT1N160-TMD40 3P / 4P FF · Icu 36 kA · 25,000 mechanical operations · S201-B10 miniature 6 kA · −25°C to +70°C

In one line: the ABB Tmax XT1N160 molded case circuit breaker (3P / 4P, 20 A / 40 A, TMD thermal-magnetic trip, Icu 36 kA, front terminals FF, 25,000 mechanical operations) and the S201-B10 miniature circuit breaker (1P, 10 A, B curve, 6 kA) cover protection from three-phase industrial distribution down to single-phase lighting circuits, IP20, for −25°C to +70°C.

Molded case circuit breakers (Tmax XT1N160 series)

ModelPoles / current / tripBreaking capacity IcuVoltageSize / weightMain use
XT1N160-TMD40 3P FF3P, 40 A, TMD R28–40 A36 kA @ 415 VAC (50 kA @ 220 V)690 VAC76.2 × 130 × 70 mm / 1.1 kgThree-phase distribution, front terminals
XT1N160-TMD40 4P FF4P, 40 A, TMD R28–40 A37.5 kA @ 415 VAC (63.75 kA @ 220 V)690 VAC101.6 × 130 × 70 mm / 1.4 kgFour-wire systems with neutral protection
XT1N160-TMD20 3P FF3P, 20 A, TMD R20–450 A36 kA @ 415 VAC (50 kA @ 220 V)690 VAC76.2 × 130 × 70 mm / 1.1 kgLow-current three-phase circuits

Miniature circuit breaker (System pro M compact S200)

ModelPoles / current / curveBreaking capacityVoltageSize / weightMain use
S201-B101P, 10 A, B (3–5 × In)Icn 6 kA / Icu 10 kA @ 230/400 VAC230/400 VAC17.5 × 88 × 69 mm / 125 gLighting and sockets in homes and light industry

XT1N160 TMD trip characteristics

Trip typeOperating conditionProtection purpose
Thermal trip (overload)Sustained overcurrent (adjustable range depends on model)Long-time protection against equipment overload
Magnetic trip (short circuit)Instant current above the set multipleCuts off short circuits immediately to protect the line
Front terminal (FF) designBoth upper and lower terminals wired from the frontSaves panel space; no side panel removal for maintenance

Comparison with similar products

ItemABB XT1N160-TMD40 3PSchneider iC65N 3P 40ASiemens 3RV (motor protection)
Breaker typeMolded case (MCCB)Miniature (MCB)Motor protection circuit breaker
Breaking capacityIcu 36 kA @ 415 VAC6 kA @ 400 VAC10–100 kA @ 690 VAC
UseMain switch / branch in industrial distributionSmall branch protectionMotor protection
Mechanical life25,000 operations20,000 operations100,000 operations

Buying tips

  • 3P or 4P: if the distribution system needs neutral protection (TN-S earthing), choose 4P; for general three-phase three-wire systems choose 3P.
  • Adjustable TMD setting: the thermal trip current of the XT1N160-TMD20 can be set within R20–450 A, so it suits many kinds of equipment.
  • S201 B curve: B-curve magnetic trip at 3–5 × In suits purely resistive loads (lighting, sockets); for small motors choose a C curve instead.
  • Spares planning: the XT1N160 series is widely used in factory distribution panels; we suggest standardizing on the same brand as ABB AF series contactors for easier maintenance.

Related: ABB AF series contactors (AF09Z / AF26 / AF116) · Schneider circuit breakers (Acti9 iC65N / NS800H) · Siemens circuit breakers (SIRIUS 3RV motor protection)