ABB circuit breakers | Tmax XT1N / S200 series, 36 kA molded case and miniature
XT1N160-TMD40 3P / 4P FF · Icu 36 kA · 25,000 mechanical operations · S201-B10 miniature 6 kA · −25°C to +70°C
In one line: the ABB Tmax XT1N160 molded case circuit breaker (3P / 4P, 20 A / 40 A, TMD thermal-magnetic trip, Icu 36 kA, front terminals FF, 25,000 mechanical operations) and the S201-B10 miniature circuit breaker (1P, 10 A, B curve, 6 kA) cover protection from three-phase industrial distribution down to single-phase lighting circuits, IP20, for −25°C to +70°C.
Molded case circuit breakers (Tmax XT1N160 series)
| Model | Poles / current / trip | Breaking capacity Icu | Voltage | Size / weight | Main use |
|---|---|---|---|---|---|
| XT1N160-TMD40 3P FF | 3P, 40 A, TMD R28–40 A | 36 kA @ 415 VAC (50 kA @ 220 V) | 690 VAC | 76.2 × 130 × 70 mm / 1.1 kg | Three-phase distribution, front terminals |
| XT1N160-TMD40 4P FF | 4P, 40 A, TMD R28–40 A | 37.5 kA @ 415 VAC (63.75 kA @ 220 V) | 690 VAC | 101.6 × 130 × 70 mm / 1.4 kg | Four-wire systems with neutral protection |
| XT1N160-TMD20 3P FF | 3P, 20 A, TMD R20–450 A | 36 kA @ 415 VAC (50 kA @ 220 V) | 690 VAC | 76.2 × 130 × 70 mm / 1.1 kg | Low-current three-phase circuits |
Miniature circuit breaker (System pro M compact S200)
| Model | Poles / current / curve | Breaking capacity | Voltage | Size / weight | Main use |
|---|---|---|---|---|---|
| S201-B10 | 1P, 10 A, B (3–5 × In) | Icn 6 kA / Icu 10 kA @ 230/400 VAC | 230/400 VAC | 17.5 × 88 × 69 mm / 125 g | Lighting and sockets in homes and light industry |
XT1N160 TMD trip characteristics
| Trip type | Operating condition | Protection purpose |
|---|---|---|
| Thermal trip (overload) | Sustained overcurrent (adjustable range depends on model) | Long-time protection against equipment overload |
| Magnetic trip (short circuit) | Instant current above the set multiple | Cuts off short circuits immediately to protect the line |
| Front terminal (FF) design | Both upper and lower terminals wired from the front | Saves panel space; no side panel removal for maintenance |
Comparison with similar products
| Item | ABB XT1N160-TMD40 3P | Schneider iC65N 3P 40A | Siemens 3RV (motor protection) |
|---|---|---|---|
| Breaker type | Molded case (MCCB) | Miniature (MCB) | Motor protection circuit breaker |
| Breaking capacity | Icu 36 kA @ 415 VAC | 6 kA @ 400 VAC | 10–100 kA @ 690 VAC |
| Use | Main switch / branch in industrial distribution | Small branch protection | Motor protection |
| Mechanical life | 25,000 operations | 20,000 operations | 100,000 operations |
Buying tips
- 3P or 4P: if the distribution system needs neutral protection (TN-S earthing), choose 4P; for general three-phase three-wire systems choose 3P.
- Adjustable TMD setting: the thermal trip current of the XT1N160-TMD20 can be set within R20–450 A, so it suits many kinds of equipment.
- S201 B curve: B-curve magnetic trip at 3–5 × In suits purely resistive loads (lighting, sockets); for small motors choose a C curve instead.
- Spares planning: the XT1N160 series is widely used in factory distribution panels; we suggest standardizing on the same brand as ABB AF series contactors for easier maintenance.
Related: ABB AF series contactors (AF09Z / AF26 / AF116) · Schneider circuit breakers (Acti9 iC65N / NS800H) · Siemens circuit breakers (SIRIUS 3RV motor protection)