中文

Illuminated push button switches: LED push buttons (22/30 mm, 1a1b) for SMT, EMS and semiconductor control panels

An input device for industrial control panels — an illuminated push button switch has a built-in LED indicator that confirms the operation and gives status feedback. Used on control panel buttons for start / stop / emergency stop / mode selection on SMT lines, EMS assembly lines and semiconductor equipment.

An illuminated push button switch is the bridge between automated machines and the human-machine interface: the operator sends commands with the button (start, stop, reset, mode select) and gets feedback from the light or display. It combines “input button + LED indicator” in one device: it can light up when pressed to confirm the operation, or stay lit during operation to show process status.

This series of industrial control panel input devices is used on SMT printers, placement machines and reflow ovens, EMS assembly and test lines, semiconductor front-end equipment and cleanroom entrance controls. A JIAHON affiliated company supplies customers throughout Taiwan.

Specifications (general specifications for industrial illuminated push buttons)

ItemRangeNotes
Mounting holeΦ16 mm / Φ22 mm / Φ25 mm / Φ30 mmΦ22 mm is common in Taiwan’s SMT/EMS industry
Contacts1a, 1b, 1a1b, 2a, 2b, 2a2b, 3a3ba = normally open (NO), b = normally closed (NC); choose by PLC input needs
Lamp typeLED / incandescent bulb / neonLED uses less power and lasts longer (typically 50,000 hours or more, case by case)
Lamp voltageDC 6 V / DC 24 V / AC 110 V / AC 220 VDC 24 V is the standard industrial PLC supply
Light colorRed / green / yellow / white / blue / orangeRed = stop / warning, green = start / running, yellow = standby; standardize by plant SOP
Button headFlush / extended / mushroom / selectorEmergency stops usually use a red latching mushroom head
ActionMomentary / maintainedMomentary for start/stop, maintained for mode selection
Rated current3 A / 5 A / 10 A @ AC 250 V (contact rating)Follow the brand data sheet
ProtectionIP65 / IP66 (front panel)For cleanrooms and general industrial environments
LifeMechanical life 1,000,000+ operations, electrical life 100,000+ operations (typical)Depends on contact load and environment

ONELITTER JDA2-BW3565: yellow, 22 mm, 220 V

This page also lists the ONELITTER JDA2 series 22 mm illuminated push button JDA2-BW3565: yellow, 1A1B contacts, lamp voltage 220 V (24 V and 110 V available on request), rated 600 V / 10 A. The manufacturer’s website does not state whether the button springs back or stays latched after pressing — please ask us to confirm before ordering. Other colors, lamp voltages and illuminated selector switches in the same series are available on request.

ItemSpecificationNotes
Brand / modelONELITTER JDA2-BW3565Product name on the maker’s website: 22@ illuminated push button 1A1B 220V yellow XB2-BW3565
TypeIlluminated push button switch (push type, with lamp)No selector positions
Series size22 mm series (JDA2)Panel cutout per the manufacturer’s dimension drawing
ColorYellowOther colors on request
Contacts1A1B (1 NO + 1 NC)—
Rating600 V / 10 AAs marked by the manufacturer
Lamp voltage220 V24 V and 110 V on request
ActionPer manufacturer specificationSpring return or maintained — please confirm before ordering

Applications

Illuminated push button switches are standard input devices on electronics manufacturing control panels. Four typical applications at SMT, EMS and semiconductor plants:

  1. Start / stop buttons on SMT machines: operating panels of printers, placement machines and reflow ovens use a green illuminated button for start (lit when running) and a red illuminated button for stop / reset. Standard Φ22 mm mounting hole. Green 1a / red 1b / DC 24 V LED
  2. Emergency stop (E-stop) safety chain: SMT lines, assembly lines and automated storage entrances require a red latching mushroom-head emergency stop button; its normally closed (NC) contact is wired into the safety circuit, so pressing it cuts power to the machine immediately and locks, requiring a manual turn to reset. Complies with ISO 13850. Red mushroom 1b latching / usually not illuminated
  3. Auto / manual mode selection on semiconductor equipment: three-position auto / manual / maintenance selection on semiconductor front-end CVD/PVD/etch tools uses a selector switch, with a key lock to prevent accidental switching. Can be integrated with PLC mode indicator lamps. 3-position selector / key lock / 1a2b
  4. EMS test fixture buttons / signal towers: ICT and FCT test fixtures at EMS plants use a yellow illuminated button to start the test, a green lamp for PASS and a red lamp for FAIL; can be combined with a tower light to show line status. Yellow / green / red 1a / DC 24 V LED flush

Selection guide: recommended specifications by use

UseButton headContactsLight color
StartFlush illuminated, momentary1a (NO)Green
StopFlush illuminated, momentary1b (NC)Red
Emergency stopRed latching mushroom1b or 2b (NC, dual safety contacts)Not illuminated (or separate red lamp)
ResetFlush momentary1a (NO)Blue / white
Mode select (auto/manual)Selector1a1b or 2a2bNot illuminated (position shows the state)
WarningIlluminated or separate indicator lamp—Yellow / orange

Why use “illuminated” buttons on control panels?

When the operator presses the start button, the button itself lights green, meaning “command sent, machine running” — no need to check the PLC display or HMI touch panel. This matters for ergonomics on high-speed lines: an operator on an SMT line focuses on the board and placement head and only glances at the button area out of the corner of the eye.

A common misconception: many newcomers think “red = always emergency stop”. In fact a normal stop button (the machine stops normally when pressed) is also red, but it is a flush momentary button; an emergency stop only counts as such if it is a red latching mushroom head. They look very different and have completely different safety ratings.

Selection steps: 5 key decisions

In practice you do not start from “what button do I want” — you work back from the actual conditions:

  1. Measure the hole size: Φ22 is mainstream, Φ16/25/30 less common. Adapter rings can be used when changing types.
  2. Confirm the use: start / stop / E-stop / mode select / reset / warning — each needs a different button head.
  3. Check the PLC side: how many contacts? Normally open (a) or normally closed (b)? Sink or source PLC inputs?
  4. Lamp voltage: DC 24 V (industrial standard) / DC 6 V / AC 110 V / AC 220 V, according to the control supply on site.
  5. Environment: cleanroom / general factory / outdoor? Start from IP65; consider IP69K only where high-pressure hot-water washdown is used; in corrosive gas environments, confirm the corrosion resistance of the housing and materials separately (IP ratings cover only dust and water).

Practical tips: what to confirm before buying

Get the number of contacts right: when asking for a quote, state the contact requirement directly, such as “my PLC DI needs 3a3b”, so you do not find out after delivery that there are not enough contacts. The model on this page has 1a1b contacts; other multi-contact models are available on request.

Check the drive circuit when converting old machines to LED: replacing an old incandescent bulb button directly with an LED module may leave it unlit (reverse polarity). First confirm whether the original LED module is AC/DC universal, or send a photo of the data sheet with your inquiry.

Standard reference: ISO 13850:2015 Safety of machinery – Emergency stop function – Principles for design, Ed. 3 — published by the International Organization for Standardization (ISO).

Trademarks: ONELITTER, IDEC, Omron, Schneider, Fuji and the model names on this page are trademarks or model names of their owners, used here only to identify the products. JIAHON is not the authorized distributor of these brands in Taiwan.

Request a quote

Need a quote or want to confirm specifications? Send us the model, contacts, lamp voltage and quantity. Request a quote →

Back to top