Cleanroom Class Comparison: How ISO 14644-1 and the Legacy Class Ratings Convert — 6 Stages from Reading the Class Table, People and Materials to Verification

A cleanroom class is set by “at most how many particles larger than a given size there are in each cubic meter of air”. The current standard is the international standard ISO 14644-1 (ISO = International Organization for Standardization; 2015 edition), which has nine classes, ISO 1 to ISO 9; the smaller the number, the cleaner, and two adjacent classes differ by a factor of 10. The legacy US Federal Standard FS-209E (Federal Standard 209E) named its classes by “the number of particles of 0.5 µm and above per cubic foot”, for example Class 100; it was cancelled in November 2001, but it is still used on the shop floor and in older documents. The approximate correspondence is: Class 100 is roughly ISO 5, Class 1,000 roughly ISO 6, Class 10,000 roughly ISO 7, and Class 100,000 roughly ISO 8. Keep two things in mind: the class covers just airborne particles from 0.1 to 5 µm, not settled dust, surface or chemical contamination; and a class does not come with buying equipment — people, materials, airflow and measurement all have to be done right, and public sources mostly say the main source is people. How to do it: first be clear which kind of “dust” is to be controlled, read the class table, decide which class and which zone, then handle people and materials, and after that prove it with a particle counter.

  • First separate four kinds of dust: the count of airborne particles (the class), the mass of outdoor air quality (PM2.5, Particulate Matter, fine suspended particles with a size of 2.5 µm or less), settled dust on surfaces, and surface and chemical contamination; the measuring methods and units all differ (Stage ①).

  • In the class table, look at the ≥0.5 µm column first: the legacy names come from this column; some of the tables in the sources at hand still keep cells from the 1999 edition (Stage ②).

  • Classes are a matter of zones: the main work area and the gowning room are each set separately; the class differences in public examples vary, and there is no standard value; airflow, filters and air changes depend on design, and the standard does not set air changes for each class (Stage ③).

  • Control people and materials first, and do the measurement at the end: gowning, entry and exit, materials and consumables come first; measurement must state clearly the occupancy state, the instrument’s calibration, the sampling locations and the volume (Stages ④ to ⑥).

Whether an SMT (Surface Mount Technology) line needs a cleanroom, see “Does SMT Dust Need Controlling? 5 Types of Foreign Matter to Control and Line Discipline“; for which consumables a cleanroom needs, see “What Are Cleanroom Consumables? Six Categories, Uses and a Purchasing Checklist at a Glance“. This article starts from “how the classes compare, how to achieve them, and how to measure them”; the scope is the airborne particle classes of ISO 14644-1 and their comparison with the legacy FS-209E. Pharmaceutical GMP (Good Manufacturing Practice) Grades A to D, biological contamination, surface and chemical cleanliness, cleanroom construction cost and HVAC design details, and anti-static measures (ESD, Electrostatic Discharge) are not covered in this article. Each stage below covers: how to do it, what public sources say, and what Jiahon can help with; sources, exceptions and clauses are in the “Notes” at the end.

Figure 1: From reading the class to proving compliance: six things. ① First separate four kinds of dust — to do: the count of airborne particles (the class); the mass of outdoor air quality; settled dust, surface and chemical contamination. What Jiahon can help with: particle counters; digital microscopes, magnifiers. ② Read the class table — to do: the upper-limit table of the nine ISO classes; the approximate classes of the legacy Class ratings; look at the commonly used column first. What Jiahon can help with: this stage is reading tables; nothing to buy. ③ Set the class and zones — to do: if the customer specification states it, follow it as written; set the main area and the gowning room separately; airflow, filters and air changes are design. What Jiahon can help with: air showers. ④ People and entry — to do: control movement and entrances first; gown up in order, take off in reverse; tacky mats, air showers, gowning rooms. What Jiahon can help with: cleanroom garments, caps, shoes, gloves; tacky mats, air showers. ⑤ Materials, consumables and cleaning — to do: materials follow a fixed route; choose wipers or paper by class; dedicated cleaning tools. What Jiahon can help with: cleanroom wipers, paper, swabs; vacuum cleaners, stainless steel tables. ⑥ Measurement and verification — to do: state clearly as-built, at-rest or operational; the instrument must be calibrated; sampling locations by area, enough volume. What Jiahon can help with: particle counters; digital microscopes. (Figure 1 caption: the six things from reading the class to proving compliance: ① first separate four kinds of dust, ② read the class table, ③ set the class and zones, ④ people and entry, ⑤ materials, consumables and cleaning, ⑥ measurement and verification; each stage lists what to do and what Jiahon can help with.)

Stage ①: First be clear which kind of “dust” is to be controlled

The “dust” written in a customer’s specification, audit checklist or contract may be four different things. First ask clearly which one it is, then go on.

MeasureUnitWhat it measuresWhat public sources say
Airborne particle classCount per cubic meter (by particle size)Airborne particles from 0.1 to 5 µmThe catalogue page of ISO 14644-1: classification looks just at particles from 0.1 to 5 µm, measured with a light scattering particle counter; it does not include ultrafine particles below 0.1 µm, and does not judge what the particles are or whether they are viable
PM2.5, PM10Mass concentration (micrograms per cubic meter)Outdoor air qualityTaiwan’s Enforcement Rules of the Air Pollution Control Act, Article 2: fine suspended particles (PM2.5) are particles with a size of 2.5 µm or less. The US Environmental Protection Agency’s standards are expressed in micrograms per cubic meter (µg/m³). Count and mass are two different units, and this article does not convert between them
Settled dustNo unified unitVisible foreign matter settled on surfaces (fibers, paper bits, skin flakes)“Does SMT Dust Need Controlling?”: what an SMT line needs to control is visible foreign matter; visual inspection, tape sampling and particle counting each measure different things
Surface and chemical contaminationAccording to their respective standardsParticles, ions and organics on surfacesISO 14644-1 itself does not deal with it; its scope is solely airborne particles

How to do it:

  • Read the specification: “Class 10,000” or “ISO 7” means the airborne particle class; “PM2.5” means air quality; “settled dust” needs a separate question about the measuring method.

  • Write both names in replies: if the customer’s older document says Class 10,000, write “ISO 7 (legacy Class 10,000)” in the report, so people on both sides can understand.

  • The class represents just the air, not that product surfaces are clean; set a separate measuring method for surfaces.

What Jiahon Can Help With:

  • Measuring airborne particles: particle counters (the page says one of the models can measure six particle sizes, 0.3, 0.5, 1.0, 2.0, 5.0 and 10 µm, with a flow rate of 2.83 liters per minute and a built-in temperature and humidity sensor; the page does not say whether it conforms to ISO 14644 or the calibration standard ISO 21501-4 — for use in formal classification, please inquire).

  • Inspecting settled dust and foreign matter: digital microscopes (direct viewing on screen, built-in measuring system), 40x handheld magnifier (folding, built-in LED lighting).

  • For prices and stock, please inquire.

Stage ②: Reading the class tables: ISO 14644-1 and the legacy FS-209E

There are two tables to read: the nine ISO classes, and the comparison with the legacy standard. For both, look at the ≥0.5 µm column first.

The table below gives the upper limits per cubic meter in ISO 14644-1:2015. “Cumulative” means: the ≥0.5 µm column already includes all larger particles.

Class≥0.1 µm≥0.2 µm≥0.3 µm≥0.5 µm≥1 µm≥5 µmLegacy approximate
ISO 110—————None
ISO 21002410———None
ISO 31,00023710235——Class 1
ISO 410,0002,3701,02035283—Class 10
ISO 5100,00023,70010,2003,520832—Class 100
ISO 61,000,000237,000102,00035,2008,320293Class 1,000
ISO 7———352,00083,2002,930Class 10,000
ISO 8———3,520,000832,00029,300Class 100,000
ISO 9———35,200,0008,320,000293,000Ordinary indoor air

“—” means this cell is not used for classification: when the concentration is too low, sampling and statistics are not reliable; when the concentration is too high, no limit is set for this cell. Class ISO 9 is used solely in the “operational” state.

The table below is the legacy FS-209E: the name is the upper limit for particles ≥0.5 µm per cubic foot.

Legacy nameUpper limit per cubic footConverted to per cubic meter (approx.)Approximate ISO class≥0.5 µm upper limit of that ISO class
Class 1135.3ISO 335
Class 1010353ISO 4352
Class 1001003,530ISO 53,520
Class 1,0001,00035,300ISO 635,200
Class 10,00010,000353,000ISO 7352,000
Class 100,000100,0003,530,000ISO 83,520,000

How to do it:

  • For the comparison, look at the ≥0.5 µm column first: the legacy names come from this column (engineering websites and university lecture notes both say so).

  • Write “approximately”, not “equal to”: after conversion the difference is just slight; for example, Class 100 converted per cubic meter is 3,530, and ISO 5 is 3,520.

  • State the edition clearly in reports: “ISO 14644-1:2015”. If the table at hand still has numbers in ISO 1’s ≥0.2 µm, ISO 2’s ≥0.5 µm, ISO 3’s ≥1 µm or ISO 5’s ≥5 µm cells, those are cells from the 1999 edition, which the 2015 edition has removed.

  • Adjacent classes differ by a factor of 10: the difference between two classes is an order of magnitude in particle quantity, so a difference of one class is not small when setting a specification.

  • If a customer writes Class 100K or Class 10K, these are abbreviations of legacy Class 100,000 and Class 10,000; when converting them to ISO 8 and ISO 7, note “approximately”.

What Jiahon Can Help With:

  • This stage is reading tables; there is nothing to buy.

Stage ③: Deciding which class and which zone, and what achieves the class

Which class and which zone are decided first; airflow, filters and air changes are for the designers to calculate, and you just need to be able to understand them.

To decideHow to do itWhat public sources say
Which classIf the customer specification or regulations state it, follow as written; if not, work backward from shop-floor defect data, and do not aim high across the boardISO 14644-1 is a method of classification; the catalogue page does not say which process needs which class. “Does SMT Dust Need Controlling?” mentions: some EMS (Electronics Manufacturing Services) plants set up ISO 8 cleanrooms for high-reliability customers such as medical and telecommunications; where the customer specification has requirements, the customer specification governs
Which zoneSet the main work area, the gowning room and the buffer zone separatelyAn example in a particle counter maker’s application document: assembly room ISO 5, gowning room ISO 7. Wikipedia: less strictly controlled cleanrooms use an anteroom (gray room) for gowning (no citation). Public examples have no standard class difference
Airflow typeDistinguish unidirectional flow (air flowing in one direction) from non-unidirectional flowA cleanroom maker’s web page: ISO 5 should use unidirectional flow; for ISO 6 it is sometimes recommended; ISO 7 and ISO 8 use non-unidirectional flow
Air changesCalculated by the designers, not a number the plant needs to memorizeA trade magazine article: ISO 14644-1:2015 does not set air changes for each class. A cleanroom maker’s empirical values (the maker itself calls them design rules of thumb): ISO 5 about 240 to 360 per hour, ISO 6 about 90 to 180, ISO 7 about 30 to 60, ISO 8 about 10 to 25 (another place on the same page says 15 to 25)
FiltersRecognize the two grades HEPA (High-Efficiency Particulate Air) and ULPA (Ultra-Low Penetration Air)Wikipedia: the US Department of Energy’s HEPA specification is removal of 99.97% or more of 0.3 µm aerosol; the European EN 1822 classifies by the most penetrating particle size (MPPS, Most Penetrating Particle Size), H13 overall 99.95% or more, H14 99.995% or more, and ULPA starts from U15 (99.9995% or more). A filter maker’s web page: H14’s efficiency at MPPS is 99.995%, with MPPS at about 0.1 to 0.2 µm
Pressure differentialThe clean zone has higher pressure than adjacent areas, so air flows outwardWikipedia: some cleanrooms are kept at positive pressure, so that when there is a leak, air leaks out; biological laboratories handling dangerous bacteria or viruses do the opposite, using negative pressure with filtered exhaust (neither has a citation)

How to look at it: where the customer specification states a class, follow it as written, and follow its zoning as written; where it does not, first check whether the shop-floor defects are caused by particles (the settled dust of Stage ①), then decide whether to spend money on a class. For airflow, filter and air change figures, do not take someone else’s empirical values as your own design values.

What Jiahon Can Help With:

  • Air shower before personnel enter: stainless steel air showers (four reference sizes: single-person single-side blowing, single-person double-side blowing, two-person and three-person, plus a cargo air shower; air velocity, number of nozzles and filtration specifications depend on the model, please inquire).

  • For prices and stock, please inquire.

Stage ④: People and entry: control the main source first

Public sources mostly say that people are the main source of contamination in a cleanroom. The figure below shows the entry route of people and materials from outside to inside (the materials part is in Stage ⑤); first look at how much people shed, then at how to dress and how to enter.

Figure 2: People and materials both go from outside to inside, with particles stopped station by station. Outside: more particles. Buffer zone: each station stops a little. Cleanroom. People — walk in from outside; tacky mat: dust on shoe soles; gowning room: cleanroom garments, caps, shoe covers, gloves; air shower: blows dust off garments; cleanroom — people: wear dedicated garments and nothing else. Materials and tools — carried in from outside; wiped first: in the gowning area with cleanroom wipers, wiped before being sent further in; material entry and exit: follow a fixed route; cleanroom — materials: cleanroom wipers and paper exclusively. Not taken in: paper, wood, cardboard boxes, pencils, cosmetics, food, drinks. Air flows outward from the clean zone: the common practice is a higher pressure in the cleanroom (positive pressure), so when the door opens, air blows outward. Schematic: the actual doors, pass-throughs and number of rooms differ according to each plant’s layout. (Figure 2 caption: people and materials both go from outside to inside, with particles stopped station by station: people pass the tacky mat, gowning room and air shower into the cleanroom; materials are wiped first, then go through a fixed entry and exit; paper, wood, cardboard boxes, pencils, cosmetics, food and drinks are not taken in; air commonly flows outward from the clean zone (schematic; each plant’s layout differs).)

ItemHow to do itWhat public sources say
How much people shedUse it to set priorities: walking sheds far more than standing, so control entry, exit and movement firstA cleanroom garment maker’s article (published 2010, revised 2020): in ordinary clothing, each person emits on average, per minute, about 182 particles of 0.5 µm and above when standing and about 3,742 when walking; the same person in different ordinary clothing differs by more than 8 times
What to wearWear complete sets of cleanroom garments, caps, shoes and gloves according to the zoneThe same article: taking a cotton tracksuit as the baseline, adding a lab coat brings standing emission down to about 30%; a complete cleanroom garment system brings it down to about 0.2% to 4.4% (the layout of the table in the source text is unclear, so just this range is quoted). A testing service company’s article: synthetic-fiber garment systems give 10 to 30 times fewer particles during vigorous movement than traditional clean garments
Gowning orderPut on in order, and take off in reverse when leavingCourse lecture notes from a US university: on entry, first step on the tacky mat, then put on shoe covers, gloves, hairnet and face mask, coverall, boot covers, and a second pair of gloves; on leaving, the reverse; the doors of the gowning room and the cleanroom must not be open at the same time
Gowning room managementLimit the number of people, leave time between two groups, no cleaning during gowningA testing service company’s article: limit the number of people and leave an interval between two groups; do not clean during gowning — dry mopping raises the total particle count by about 5 times
Not taken inCosmetics, food, drinks, paper, wood, cardboard boxes, erasers, pencilsThe same university lecture notes: paper, wood, cardboard boxes, erasers and pencils must not go in, nor cosmetics, food or drinks; just ballpoint pens and cleanroom paper may be used
Worn properly when comfortable to wearWhen someone says the straps are too tight, first compare size, weight and length, then look at how new the elastic is and the sewn-in tensionA common practice on production lines; hairnet caps and face masks are both compared this way

How to look at it: first get entrances under control (gowning, tacky mats, air showers), then control materials and airflow. Once the gowning route is loose, none of the later stages can make up for it.

An example of tracking down a problem: during trial production, the abnormalities were mainly contamination of the gold fingers on the back side. The investigation checked four aspects item by item: operator technique, whether the cleaning machine could remove it, whether the carriers were clean, and whether incoming material had problems; it was confirmed to be a problem within the process, unrelated to incoming material. The type of cause was the working method: gloves were worn, and the source document considered that gloves could still become contaminated during work; gloves were initially set to be changed every 4 hours, and the source document considered that the frequency needed to be redefined. The countermeasures were to reset the glove change frequency, mark a fixed visual inspection area with zebra stripes, clean with alcohol before visual inspection, and wash the carriers weekly. This example is a reminder: wearing gloves does not mean there will be no contamination, and the glove change frequency and the visual inspection location also need control; the source document used “could” for gloves becoming contaminated, with no actual measurement.

What Jiahon Can Help With:

Stage ⑤: Materials, consumables and cleaning

Once people move correctly, materials and consumables also need to follow a fixed route and be things that do not shed.

ItemHow to do itWhat public sources say
Material entry and exitMaterials and portable equipment also follow a fixed route and are wiped before going inThe catalogue page of ISO 14644-5:2025: the operational control plan includes installation and maintenance of fixed equipment, entry and exit of materials and portable equipment, personnel management and gowning, cleaning and maintenance, and monitoring. Lecture notes from a US university: avoid bringing laptops and mobile phones as far as possible; when they must be brought, wipe them in the gowning area with cleanroom wipers wetted with isopropyl alcohol before going in
Materials not taken inThings that shed, such as paper, wood, cardboard boxes and pencils, are not taken inWikipedia: paper, pencils and fabrics of natural fibers are often excluded; the page says they shed in use (no citation); the same university lecture notes say the same
WipingChoose wipers or paper by classJiahon’s product page: for ISO Class 6 and above, cleanroom wipers are recommended; the page lists three wipers, one marked ISO Class 6 to 8 and two marked ISO Class 4 to 6; the wiping paper is not marked with a class and is recommended for general cleanroom work or the exterior of equipment
CleaningMops and buckets for cleaning are dedicated and not mixed with use elsewhereWikipedia: cleanrooms use dedicated mops and buckets exclusively (no citation)
Tables and racksSurfaces smooth, wipeable and non-shedding; material and surface treatment according to the customer specificationThis site did not find a reliable general rule; requirements differ by customer and by class
Stationery and paperUse cleanroom paper and ballpoint pensThe same university lecture notes: just ballpoint pens and cleanroom paper may be used

How to look at it: treat “does it shed” as the single criterion for whether something goes in; do not judge by whether it is expensive or whether it carries the word “cleanroom”.

What Jiahon Can Help With:

Stage ⑥: Measurement and verification: how to prove it really is that class

Whether it is someone else’s classification report or your own verification, look at the same few things: which state, which instrument, how many locations, and how much is sampled at each.

ItemHow to do itWhat public sources say
StateThe report states whether it is “as-built”, “at-rest” or “operational”, and confirm which one the customer requiresA particle counter maker’s web page (the three states of ISO 14644-1): as-built is the room completed, with equipment and services connected, but without production equipment and personnel; at-rest is equipment installed and operating as agreed, with no personnel; operational is equipment operating with the specified number of personnel present
InstrumentUse a light scattering particle counter and confirm its calibrationThe catalogue page of ISO 21501-4:2018: this document is the calibration and verification method for light scattering particle counters for cleanrooms, and conforming instruments are used for classification under ISO 14644-1 and ISO 14644-2. A technical services company’s article (2016): the 2015 edition requires counters to be calibrated to this standard; some counters cannot pass all the tests, and whether to use them should be recorded in the report
Number of sampling locationsLook up the table by area; locations should be evenly distributed and representativeTable A.1 of ISO 14644-1:2015 (reproduced on a cleanroom consumables maker’s web page): look up the table by area; the number of locations rises from 1 (2 square meters or less) up to 27 (1,000 square meters or less); when falling between two values, take the larger; for unidirectional flow, use the cross-sectional area perpendicular to the airflow. The older edition (1999) used “number of locations = square root of the area”; taking 34 square meters as an example, the old formula gives 6 locations, while the 2015 edition table gives 9 (8 for 32 or less, 9 for 36 or less, take the larger) (this article’s own comparison)
How much to sample at each locationSample enough volume and enough time at each locationA particle counter maker’s application document: minimum volume per location = (20 ÷ the class limit at the particle size of interest) × 1,000 liters, at least 2 liters and at least 1 minute per location. Example: ISO 5, ≥0.5 µm gives 5.68 liters; with a counter flow rate of 2.83 liters per minute, sample for about 2 minutes
JudgmentCompare each location’s result with the class limit, following the standard’s statistical methodA technical services company’s article: the 2015 edition raised the minimum number of sampling locations, with the aim of “95% confidence that at least 90% of the area does not exceed the limit”; the older edition calculated a 95% upper confidence limit (the application document above uses the old method). For details, see the full text of the standard
How oftenRepeat classification periodically according to risk, and use a monitoring plan day to dayThe catalogue page of ISO 14644-2:2015: sets the minimum requirements for a monitoring plan. The application document above says: ISO 14644 sets the maximum interval for reclassification, 6 months for ISO 5 and cleaner, and 12 months for higher class numbers. A technical services company’s article: the classification interval is set by risk, commonly once a year, and can be extended when continuous monitoring is stable. The full text of ISO 14644-2 was not read; for details, the full text governs
What it cannot measureSettled dust, surface and chemical contamination are measured separatelySee Stage ①

How to look at it: when you get someone else’s classification report, first look at four things: the standard and year, the state, the instrument’s calibration, and the number and position of sampling locations. If any one of the four is missing, the numbers cannot be compared with yours.

What Jiahon Can Help With:

  • Routine self-checks: particle counters (see Stage ①; whether a counter for formal classification needs to conform to ISO 21501-4 is not stated on the page, please inquire).

  • Inspecting foreign matter: digital microscopes.

  • For prices and stock, please inquire.

Further reading

To go through the related process steps together, you can read these next:

Notes: sources and exceptions

The following is for those who need to check; skipping it does not affect the practices above. Where your customer’s specification or your plant’s written specification differs from this article, they govern.

Sources for each practice

PracticeContentSource
Class table and legacy comparisonUpper-limit table of the nine classes, legacy names and conversion, differences between the 2015 and 1999 editionsCatalogue page of ISO 14644-1:2015 (catalogue page alone; the full text of the standard was not read), a particle counter maker’s class table (maker’s web page; the page is marked as published July 15, 2026; the ≥5 µm column for ISO 5 still lists the 1999 edition figure, which this article does not adopt), a cleanroom consumables maker’s class table (maker’s web page; with table notes), the Wikipedia Cleanroom entry (the table has no direct citation; cross-checked against the previous two), a technical services company’s explanation of the 2015 revision (2016; lists the cells removed in the 2015 edition)
Legacy FS-209EClassification method, per-cubic-foot and per-cubic-meter comparison, cancellationAn engineering website’s Federal Standard 209 page (the per-cubic-meter figure for Class 100,000 is printed as 3,350,000, which is a misprint; this article corrects it to 3,530,000), an automation equipment supplier’s blog (maker’s article; January 5, 2017; says it was replaced by ISO in November 2001, with a comparison table), the Wikipedia Cleanroom entry (says it was cancelled by the US General Services Administration on November 29, 2001)
Four kinds of dustDefinition and unit of PM2.5Enforcement Rules of the Air Pollution Control Act, Article 2 (definition of fine suspended particles; this article did not find the values of the Taiwan standard and does not quote them), the US Environmental Protection Agency’s PM basics, the US Environmental Protection Agency’s standards table (unit in micrograms per cubic meter; US figures, whose values this article does not quote)
Airflow, air changes, filters, pressure differentialUnidirectional and non-unidirectional flow, air changes, HEPA and ULPA, positive and negative pressureA cleanroom maker’s class explanation page (maker’s web page; calls them design rules of thumb; the air changes for ISO 8 are written two ways on the same page), a cleanroom trade magazine’s HVAC calculation article (August 6, 2019; just the first part was read, the full text is paywalled), the Wikipedia HEPA entry (classification table of EN 1822 and ISO 29463; the table layout has errors, so this article quotes just the lower limits of H13, H14 and U15), a filter maker’s EN 1822 explanation page (maker’s web page; the page is marked as created March 10, 2021; H14 and MPPS), the Wikipedia Cleanroom entry
People and entryShedding, garment systems, gowning order, gowning room management, things not taken inA cleanroom garment maker’s article “People as a Source of Contamination” (Germany; published 2010, revised 2020; maker’s article; table layout unclear), a testing service company’s gowning article (the author is a microbiology consultant; the page shows just 7 March, with no year), course lecture notes from a US university (no unit given; the page shows no date; that cleanroom uses legacy Class 1,000; the gowning order is that laboratory’s rule, not a standard)
Materials and cleaningOperational control plan, material entry and exit, materials not taken inCatalogue page of ISO 14644-5:2025 (catalogue page alone), the course lecture notes from a US university, the Wikipedia Cleanroom entry
Measurement and verificationThree states, instrument and calibration, number of sampling locations, sampling volume, judgment, frequencyCatalogue page of ISO 14644-2:2015, catalogue page of ISO 21501-4:2018, a particle counter maker’s explanation of the states (maker’s web page; the page shows no date), Table A.1 as reproduced by a cleanroom consumables maker (maker’s web page; the full text of the standard was not read), a particle counter maker’s application document (maker’s document; the page shows no date; the number of sampling locations still uses the 1999 edition formula; the volume formula is worked back from the example), the technical services company’s explanation of the 2015 revision
Jiahon’s own dataSpecifications on each product pageJiahon product pages and articles
Production line practiceHow to compare when hairnet caps or face masks are said to be too tight: first compare size, weight and length, then look at the elastic (company, part numbers, conditions and year not given)Summary of production line practice (source documents not public)

Standards referenced

For the specifications cited in this article, please refer to the current edition from each issuing body.

This is the general case and still depends on the individual case.

Exceptions and limits

  • Nature of the data: the class tables in this article were cross-checked among the standards body’s catalogue pages, makers’ web pages and the reproduction on Wikipedia; the full text of ISO 14644 (paywalled) was not read. Figures follow the edition of the standard you have at hand. The standards body’s pages also show that ISO 14644-1 and ISO 14644-2 are under systematic review (July 2026), with no result stated on the pages; the pages also say they were confirmed in 2021 and remain current.

  • Class tables: tables from different sources differ in some cells. ISO 1’s ≥0.2 µm, ISO 2’s ≥0.5 µm, ISO 3’s ≥1 µm and ISO 5’s ≥5 µm are 1999 edition figures that the 2015 edition removed (revision explanation); this article uses the 2015 edition, and three sources agree on cross-checking. The 2015 edition also has intermediate classes with decimals (for example ISO 8.5), which this article does not list.

  • Legacy conversion: the per-cubic-meter figures are converted from per cubic foot (1 cubic foot is about 0.0283 cubic meters) and checked against the engineering website’s table. “Approximately” is the sources’ wording, not legal equivalence; the legacy standard also had ≥5 µm limits for some classes, which this article does not list.

  • Human shedding: in the cleanroom garment maker’s experiment, 182 standing and 3,742 walking are averages, with individuals differing by more than 8 times; the column correspondence for the 0.2% to 4.4% of complete systems is unclear in the layout of the source text. The testing service company’s article page shows just 7 March, with no year; “10 to 30 times” is a comparison of synthetic-fiber garment systems during vigorous movement.

  • University lecture notes: no unit given; the page shows no date; the gowning order is that laboratory’s rule, not a standard.

  • Air changes and airflow: the standard does not set air changes for each class; makers’ empirical values are a starting point for design, not requirements, and cannot be compared with one another.

  • Sampling locations and volume: sampling locations use Table A.1 of the 2015 edition (reproduced web page); the sampling volume formula and “at least 2 liters, at least 1 minute” come from a maker’s application document, and the formula is worked back from the example; this article did not recalculate the statistical results in that document item by item, and cites just the method, not the results. The 34 square meter comparison is this article’s own calculation from two sources.

  • Judgment and frequency: the judgment methods of the 2015 and 1999 editions differ, and this article gives just the direction; the retest frequency differs among sources — the full text of the standard governs, together with customer specifications and risk.

  • This article’s own summary and recommendations: the following are this article’s own summary from the sources, which the sources do not state in this way: dividing “dust” into four kinds; writing both the ISO and legacy names in reports; controlling people and entrances first, then materials; first checking whether defects are caused by particles before deciding whether to spend money on a class; the four things to look at in someone else’s classification report.

  • Production line practice: production line practices differ by plant conditions; please follow your own process validation.

  • Scope: this article does not cover pharmaceutical GMP Grades A to D, biological contamination (covered by separate standards), surface and chemical cleanliness, cleanroom construction cost and HVAC design details, or anti-static measures.

  • Equipment and products: specifications are as on each product page. This article lists just items stated on Jiahon’s product pages; for anything else, please inquire. The cleanroom garment page says “Class 100 to 10,000 (ISO Class 5 to 7)”; the “Class A / Class B” wording also on that page is not adopted in this article; the particle counter page does not say whether it conforms to ISO 14644 or ISO 21501-4; the air shower page does not give air velocity or filtration specifications; the vacuum cleaner page does not give an ISO class.

This article is a summary of the general case, not a restatement of standard clauses, and not an endorsement of any cleanroom maker, instrument maker or consumables maker, nor does it constitute an assurance for your products and processes, nor is it safety or regulatory advice. Please follow your customer’s specifications, your plant’s written specifications, local regulations and your own validation; this is the general case and still depends on the individual case.