中文

Production Line Turnover Cart Customization Guide: From a Sketch to the Cart Your Line Can Actually Push

Production line carts, carriers, fixtures and ESD packaging

Process & Fixture Design | General Customization

On an electronics plant production line, the “turnover kit” — carts, carriers, jigs and tools, ESD anti-static packaging — bought separately from five suppliers versus bought together from one: the difference is not in the unit price. This article takes stock of what each of the five FATP stations has to solve, explains why ESD protection often breaks at the last caster, and includes an analysis we actually carried out: why a 2.5-meter-tall, roughly 2-tonne full rack tilts when pushed onto a pallet, and four solutions.

Jiahon Group ・ Engineering Department | Production bases: Zhunan Plant and Toufen Plant, Miaoli

Contents

30-second summary: if you read just this section

What we make

Carts ・ jigs and tools ・ ESD kits ・ sheet metal and aluminum extrusion structural parts

  • All manufactured in our own plants — Zhunan Plant and Toufen Plant, Miaoli

  • Carts in 13 series plus fully custom; ESD supplied as one whole chain, from foam, reel trays, racks and turnover boxes to grounding chains

  • The AGV mobile chassis uses an AGV chassis maker’s chassis; Jiahon draws the cart-underside interface specifications

How we work

Filling the gap, not taking over

  • You give us a sketch and requirements; we turn it into a drawing that can be built

  • Production starts just after the drawing is confirmed — the formal design and model numbers follow the drawings issued by your company

  • A sample cart can be arranged for a trial on your production line; please inquire with sales about the terms; if it does not suit you, that does not affect our dealings

What problems we have solved

One example: a 2.5 m, 2 t full rack tilting when pushed onto a pallet

We did not quote first; we first turned it into a problem that can be calculated:
17.8° critical tipping angle in the direction of travel
(top-heavy 5:1 configuration)

The push uses up 20.9° bridge plate slope 9.6° + one sudden stop 11.3°

So the missing 3.1° cannot be made up; the answer lies in structure and process

→ See the full analysis in the case study below

Three steps to start Give us a sketch or a photo of the production line → We produce a specification drawing and quotation → A sample cart goes onto your line for a trial

A production line’s turnover kit: five stations, and what each really has to solve

Taking electronics manufacturing FATP (Final Assembly, Test and Packaging) as an example, five stations are passed from incoming material to shipment. Each station’s turnover needs are different; forcing the same off-the-shelf cart onto all of them usually starts causing problems at the third station.

A production line's turnover kit: five stations, and what each really has to solve

① Incoming material ・ WIP staging

  • 8-GPU-class server nodes commonly weigh about 95–107 kg (depending on each server maker’s specifications)

  • Heavy-duty specifications are set per node, not forced onto off-the-shelf products

  • Boxed material goes on a turnover box hand truck, transferred without pallets; boards go in drawers instead of stacked shelves, one batch per compartment

① Incoming material ・ WIP staging

② Rack assembly

  • Server nodes of nearly 100 kg have to be lifted into a 2.5-meter rack; loading purely by hand is not recommended

  • Busbars and liquid-cooling quick connectors are all blind-mated; a misaligned insertion means bent pins and leaks

  • Positioning jigs cost little; bent pins and leaks cost a lot

② Rack assembly

③ Cable routing and cable labeling

  • Inside a liquid-cooled rack, coolant lines and signal cables run in parallel

  • Bend radius and routing direction directly affect maintenance and yield

  • Cable label management: one wrong cable costs a day of tracing

③ Cable routing and cable labeling

④ Testing ・ liquid cooling

  • 8-tier server smart test cart: high-strength sheet metal + anti-static coating

  • Liquid-cooled AI racks have a far higher power density than conventional air-cooled racks

  • Liquid-cooling leak testing and filling are a new required course

④ Testing ・ liquid cooling

⑤ Packaging and shipping

These five stations in one sentence ① and ③ are “afraid of knocks, afraid of mess”, ② and ④ are “afraid of weight, afraid of misaligned insertion”, and ⑤ is “afraid of tipping over”. The first four stations are solved with carriers, jigs and tools, and specialized equipment; the fifth station depends on structure and process — which is why this article gives it a separate case study.

Custom carts: these are the ones made in our own plants

All custom carts are made in-house at the Zhunan and Toufen plants in Miaoli — specifications are set to your company’s boards, and production starts just after the drawing is confirmed. Photos and design points of five custom shipment records (12-tier stainless steel drawer cart, 6-tier aluminum extrusion roller track cart, 7-tier roller track roller cart, 15-tier stainless steel shelf cart, 32-tier double tray cart) are written up in the case “Custom cart overall proposal | Anti-static drawer carts and roller track carts — project cases“. When choosing a cart, you can first match like this:

  • Boards need one batch per compartment, without interfering with each other → 12-tier stainless steel drawer cart (can be lined with anti-static EVA foam; the same series also has a stainless steel 7-tier drawer cart)

  • Material boxes fed in on rollers, several carts coupled into a train → aluminum extrusion roller track cart, roller track roller cart (tier spacing and roller length made to order according to box size)

  • Narrow aisles, two-way passing → stainless steel shelf cart with a narrow body of about 0.6 m

  • Tray turnover → single 16-tier / double 32-tier tray cart (trays specified to the actual tray size; can be paired with anti-static square trays)

Standard series (minor modifications possible; for stock please inquire)

Beyond carts: the jigs, tools and structural parts used at the stations are also made by us

Isometric schematic gold = node in half-inserted state

Isometric schematic gold = node in half-inserted state.

  • Rack positioning jig
    Keeps everything square throughout assembly, with a datum for fastening

  • Node slide rail alignment guide
    100-kg-class nodes lined up with the rail, in place in one go

  • Blind-mate alignment protection jig
    Busbars and liquid-cooling quick connectors are all blind-mated; a misaligned insertion means bent pins and leaks

  • Cable comb ・ bend radius jig
    Consistent bend radius; coolant lines and signal cables inside the liquid-cooled rack do not interfere with each other

  • Fastening angle brackets ・ anti-collision corner guards
    Rack and base locked into one unit; however high the center of gravity, they do not come apart

  • ESD grounding kit
    Grounding chains and anti-static mats, conductive casters, anti-static foam linings — built in from the structure

ESD grounding kit: grounding chain, anti-static mat and conductive casters

Roller + side guide rail sliding table

Mass-production technology transferred

The metal rollers run along a single axis, and guide rails on both sides lock the node on a straight line — 95–107 kg slides sideways into the rail, with zero lifting all the way and no sway. The strenuous motion at the assembly station changes from “lifting” to “pushing”.

Materials SUS 304 sheet metal (strength ・ acid and alkali resistance ・ polished and clean) | aluminum extrusion (modular ・ quick to change and quick to expand) | POM (polyoxymethylene, acetal) ・ EVA (contact surface protection ・ cushioning and anti-collision)

ESD is not a part, it is a chain

From the production line to shipment, a board passes through foam, reel trays, racks, turnover boxes, the cart body, the grounding chain, the casters, and then to the floor. If the resistance of any link on this path is wrong, all the protection before it amounts to zero. Anti-static protection is not achieved by “buying the anti-static version of every part”; it is a continuous discharge path.

If the resistance of any link on this path is wrong, all the protection before it amounts

Anti-static EVA foam

Die-cut to the board ・ form-fitting enclosure

Can be slotted and die-cut to the board, with the whole lining replaceable; drawer and tray linings both use it.

Anti-static EVA foam

Anti-static SMT reel box ・ square tray

Containers for reels and small parts

Stackable; selected to match the reel size. For thin parts there are also black anti-static soft trays / corrugated boxes.

Anti-static SMT reel box ・ square tray

Anti-static PCB loading/unloading rack

SMT magazine ・ board staging

Slot width 5 mm ・ pitch 10 mm | surface resistance 10⁶–10⁹ Ω | heat resistance in three grades: 100 / 120 / 230 ℃.

Anti-static PCB loading/unloading rack

Anti-static turnover box ・ folding box

Containers for moving between stations and between plants

With lids, multiple sizes, stackable; for sorting needs there is also a turnover box with removable dividers.

Anti-static turnover box ・ folding box

ESD grounding kit

Making the whole chain truly grounded

Anti-static table mats, anti-fatigue floor mats, wrist straps, grounding chains, conductive casters; for online monitoring you can use the multi-channel grounding alarm JHKL-10 (monitors three channels at once: wrist strap, table mat and equipment).

Static is grounded just when it has traveled this whole path If the resistance of any link is wrong, the whole chain is broken

  • Board

  • EVA lining

  • Reel tray / rack

  • Turnover box

  • Cart body

  • Grounding chain

  • Conductive caster

  • Floor

The break point that is often overlooked: the casters

Ordinary PU casters are insulators. You bought the anti-static versions of the foam, the racks and the turnover boxes, yet when the path reaches the last caster, it still cannot reach ground. This is the link easily missed when buying separately — because no one is responsible for looking at “the whole chain”.

What to watch for: “low resistance” is not the problem; “insulating” is. Surfaces in contact with the board (foam, reel trays, racks, box bodies) need to fall within the static-dissipative range of 10⁶–10⁹ Ω, to avoid sudden discharge; but the section from the grounding chain and conductive casters to the floor is the discharge path, and what it requires is low-resistance conduction. The resistance of ordinary PU casters is so high that they are effectively insulating, and the path breaks right there.

We recommend measuring the contact surfaces quarterly with a surface resistance meter, and verifying the conduction resistance of the grounding path according to ANSI/ESD S20.20. The difference in magnitude between these two sections can be seen from the ranges of the monitoring equipment: the JHKL-10 multi-channel grounding alarm measures wrist straps and table mats over a range of 0–99.99 MΩ, but measures equipment grounding over a range of 0–99.99 Ω.

Foam, trays, drawers: choose the right carrier with one table

Comparison of the three carrying methods in protection level, cost structure, batch isolation, pick-and-place speed and use

Custom EVA foamTrayDrawer cart
Protection levelHigh — die-cut to the board, form-fitting enclosureMedium — standardized positioningMedium-high — held on slide rails, not suspended
Cost structureDie cost + amortized per pieceLow unit price in mass productionOne-time investment, no consumables
Batch isolationWeakMediumStrong — one batch per compartment
Pick-and-place speedSlowMediumFast — pull out with one hand
Common usesHigh-value single boards ・ shipping protectionHigh volume ・ automated loadingIn-plant turnover ・ mixed lines with multiple batches

Mix and match: drawers + foam lining, trays + single or double tray carts — three carrying methods, all supplied from one source.

Automation comes later, it is not a precondition: AGV-ready design for carts

Pushing everything by hand today is entirely fine. The same architecture can be connected to automation later — the difference lies just in whether that one extra line was drawn when the order was placed.

Under-ride lifting: how an AGV takes over the same hand-pushed cart

① Hand-pushed cart in position

① Hand-pushed cart in position — AGV on standby alongside.

② Drives under the cart

② Drives under the cart — aligns with the lifting surface.

③ Lifts ・ carries the whole cart away

③ Lifts ・ carries the whole cart away — casters off the floor.

The mobile chassis uses an AGV chassis maker’s chassis; we draw the cart-underside interface

SDM500-D228 under-ride lifting

SDM500-D228 under-ride lifting — rated 500 kg ・ own weight 244 kg | L990×W776×H305 mm | lifting stroke ≤ 50 mm | natural navigation + QR Code | ≤ 1.2 m/s (72 m/min).

MK1000-81 under-ride towing

MK1000-81 under-ride towing — towing ≤ 1,000 kg ・ own weight 350 kg | L1671×W540×H329 mm | magnetic navigation + RFID landmarks | ≤ 40 m/min (0.67 m/s).

Source of specifications and photos: the AGV chassis maker’s product specification sheets (SDM500-D228 / MK1000-81, 2022 edition).

Figure 19: Division of work at the cart-underside interface. Jiahon: cart body ・ carriers ・ jigs and tools ・ ESD kits ・ sheet metal and aluminum extrusion structural parts. Cart-underside interface (the boundary): clearance; lifting surface; positioning; load. ↑ These four specifications are drawn by Jiahon according to the AGV model your company selects. AGV chassis maker: mobile chassis ・ navigation ・ dispatch system.

AGV-ready: the extra line drawn at the design stage

  • Under-cart clearance and entry channel — made to order according to the selected AGV model

  • The lifting contact surface and positioning are marked when the drawing is issued

  • Frame rigidity for lifting conditions; welds calculated for lifting

  • Floor conditions: under-ride types have requirements for floor flatness, which need to be confirmed on site

Key point The hand-pushed cart you buy today can be tomorrow’s AGV carrier. Building it in is mainly a matter of dimensions and datums, with a limited added cost; adding it afterwards amounts to remaking the whole cart frame.

Note that the load must match: the cart’s own weight plus its load must be within the rating of the selected AGV. Taking the SDM500-D228 (rated 500 kg) as an example, a heavy-duty cart in the 500 kg load class would need to be paired with a higher-tonnage model instead.

Phase 1 | Now

All newly purchased carts AGV-ready

A decision with a limited cost increase, in exchange for options over the next ten years.

Phase 2 | Pilot

One station, one line ・ 2 under-ride AGVs

Small-scale validation of the material flow and Cycle Time; let the data speak.

Phase 3 | Expansion

Full automation between stations + dispatch system

Cart trains, route network and charging planned together in one go.

Case study: why a 2.5-meter, 2-tonne full rack tilts when pushed onto a pallet

A partner company raised the issue: a full rack 2.5 meters tall and weighing about 2 tonnes tilts when pushed onto a pallet over roller tracks. We did not quote first; instead we first turned it into a problem that can be calculated. Below are the complete analysis process and four solutions — the same analysis can be redone for your company’s actual configuration.

1. Conditions provided by the user side, and our model

Conditions provided by the user side

  • Rack height 2.5 meters (including base)

  • About 2 tonnes fully loaded

  • Top-heavy, with a high center of gravity

  • Pushed onto a pallet over roller tracks; tilts during the push

Our model

  • Parametric simulation of top-to-bottom weight ratios of 1:1 ・ 2:1 ・ 5:1

  • Models just the relative weight distribution of the upper and lower sections; independent of the absolute weight of the full rack

  • Critical tipping angle θ = arctan (support half-distance ÷ center-of-gravity height)

  • The support surface is taken as the outer edge of the base, using a common AI rack base of 600 × 1,068 mm as an example

  • Assumption: if the actual support polygon is the caster wheelbase or the roller track gauge, set in from the outer edge of the rack, the critical angle will be lower still than in the table below

Geometric schematic of the full rack's critical tipping angle

Geometric schematic of the full rack’s critical tipping angle.

The geometric schematic uses the 2:1 configuration (center-of-gravity height 1.46 meters, lateral critical angle 11.6°) as an example. The 5:1 configuration used in this article’s conclusion has a higher center of gravity (1.67 meters) and a smaller critical angle.

2. Critical tipping angle: once calculated, you know why it tilts

Critical tipping angle θ = arctan (support half-distance ÷ center-of-gravity height). The two directions must be calculated separately: the direction of travel is the direction of pushing onto the pallet, with a support half-depth of 534 mm; lateral is left-right, with a support half-width of just 300 mm.

Center-of-gravity height and lateral and travel-direction critical tipping angles under three top-to-bottom weight distributions

Top-to-bottom weight ratioUpper half / lower half (relative units ・ independent of total weight)Center-of-gravity heightLateral critical angle (support half-width 300 mm)Travel-direction critical angle (support half-depth 534 mm)
1 : 11 / 11.25 m13.5°23.1°
2 : 12 / 11.46 m11.6°20.1°
5 : 15 / 11.67 m10.2°17.8°

Red background = insufficient margin in the direction of travel (below the push budget of 20.9° below). A critical angle below the threshold means there is a risk of tipping over, not that it will necessarily tip over.

Push budget: how many degrees this trip uses up

This tilt occurred while pushing onto the pallet, that is, in the direction of travel. Adding up the tilt angles this trip uses up:

  • Bridge plate slope 9.6° — back-calculated from a pallet surface height of 150 mm and a bridge plate length of about 0.9 meters (arcsin 0.15 ÷ 0.9). The shorter the plate, the steeper the slope.

  • One sudden stop 11.3° — taking 0.2 g as an estimate of handling deceleration (arctan 0.2). Pushing 2 tonnes by hand cannot reach 0.2 g (that would take about 400 kgf), but the jolt of hitting a step, a stop block or the edge of the pallet can.

  • Total 20.9° — already exceeds the 5:1 configuration’s travel-direction critical angle of 17.8°, and also exceeds the 2:1 configuration’s 20.1°.

Key concept: the critical tipping angle is independent of total weight

The critical tipping angle depends just on geometry — the support half-distance and the center-of-gravity height. Whether the full rack is 2 tonnes or 1.4 tonnes, this table holds. Total weight affects the size of the pushing force and the floor load, not the critical angle itself; as for whether it will actually tip over, that also depends on the slope angle and deceleration actually reached during the push.

Lateral: even less margin, but no threshold that can be cited

The lateral support half-width is just 300 mm, and the critical angle is about 8–10° less than in the direction of travel (the 5:1 configuration has just 10.2° left). Pushing at an angle, a caster on one side catching on an edge, a bridge plate uneven from left to right — all of these use up this margin. We have no lateral acceleration standard value that can be cited, so we make no judgment on the lateral direction — but the number itself shows: this rack’s tolerance for “going wrong sideways” is far smaller than for “going wrong front-to-back”; on-site testing is recommended.

Two things related to total weight

  • Pushing on level ground 40–100 kgf — estimated with rolling resistance μ = 0.02–0.05; a 9.6° bridge plate adds a slope component of about 334 kgf

  • Point load per caster 500–667 kg — 500 kg when shared equally among four casters; 667 kg when the floor is uneven and just three casters touch the ground. For raised floor load capacity, on-site confirmation is recommended.

The slope angle, deceleration and pushing force above are all estimates, and still depend on the individual case’s bridge plate length, floor, wheel diameter and wheel material.

Conclusion On this trip onto the pallet, the slope angle plus one sudden stop alone use up 20.9°, while the 5:1 configuration’s travel-direction critical angle is just 17.8°. The missing 3.1° is not something operators can make up by being more careful — it has to be tackled through structure and process.

3. Four solutions: one addresses the root cause, one assists, two can go in today

Solution ② Recommended backbone Reverse the process: the cart does not go onto the pallet, the pallet comes to the cart — there is no longer any “onto the pallet” step at all

  • The crate base is the pallet
    Skid base: the base itself is the forklift interface

  • The rack rolls in on level ground
    The base sits directly on the floor; just a short bridge plate is needed to make up the thickness of the base board, and the push is nearly horizontal

  • Leveling feet set down
    Feet lowered, casters off the floor — rolling mode ends

  • Locked with L-shaped angle brackets
    Rack and base locked into one unit; however high the center of gravity, they do not come apart

  • Crate assembled from four side panels
    The crate is assembled around the rack, rather than the rack being squeezed into a crate

  • Forklift picks up the base
    ISPM-15 heat treatment + tilt / shock indicator labels

Solution ① Site assistance Eliminate the height difference: make the “slope” disappear from the system

Solution 1: site assistance — eliminating the height difference

A scissor lift platform raises the pallet surface to the same height as the roller tracks, bringing the two main sources — the ramp angle and the bump at the step — straight to zero.

Platform load rating ≥ 2.5 t

Consistent with ISTA RTST Safer Handling Practices for Server/Storage Rack Products Version 3 (April 2012) (that guideline recommends a lower limit of 1,800 kg for lifting equipment capacity, with 1,800–2,500 kg recommended in practice). Made in-house by Jiahon; roller tracks can be added to the platform surface.

Solution ③ + ④ Transition period No change to the site, no change to the process; can go in today

  • Side guide rail gantry — locks the possible tilt angle within a safe value

  • Retractable anti-tip outrigger wheels — enlarge the support base at the moment of transfer

  • Winch ・ powered towing for speed control — takes “human bursts of force” out of the system

  • Center-of-gravity management — move heavy parts lower; calculated with the 5:1 configuration (center of gravity 1.67 meters), each 10 cm lower gains about 1.1° more in the direction of travel and about 0.6° more laterally

These four are risk-reduction measures for the transition period and do not replace Solutions ① and ②. When the site and the process cannot be changed for the time being, you can first bring down the possible tilt angle and the human variables, and remove these measures once the backbone solution is in place.

Compared with the industry guideline ISTA RTST Safer Handling Practices for Server/Storage Rack Products Version 3 (April 2012): manual handling of a full rack needs 3 or more people, and ramps are recommended not to exceed 5°. Estimated with a pallet height of 150 mm and a bridge plate length of 0.9 meters, the slope of the section pushing onto the pallet is about 9.6° — already nearly twice the guideline’s recommended upper limit.

Data sources Server node weight 95–107 kg: common values for 8-GPU-class server nodes (depending on each server maker’s specifications) | base geometry 600×1,068 mm: using a common AI rack base as an example | rack height and full rack weight: provided by the user side | handling recommendations: ISTA RTST (Rack Transport Stability Team) Safer Handling Practices for Server/Storage Rack Products Version 3, April 2012, Traditional Chinese edition. The tipping angle values are results of this article’s analytical model, not measured values.

Buying separately saves on bargaining; buying integrated saves the cost of things not fitting

For the same production line’s turnover equipment, buying from five suppliers versus buying from one: the difference is not in the unit price.

Four things you run into when buying separately

Dimensions do not match Boxes do not fit into racks, racks do not push into carts, carts do not match the AGV underside — every interface is the boundary between two suppliers, and no one is responsible for the whole.
ESD grades inconsistent Inconsistent grades are hard enough to manage in themselves; more critically — ordinary PU casters are effectively insulators, so the discharge path breaks at the casters, and however good the anti-static parts bought before them, they are wasted.
Blame-shifting when problems occur Is a scratched board the foam’s fault or the drawer’s? Is electrostatic breakdown the rack or the caster? Five suppliers, five versions.
Lead times each going their own way One item arrives late, and the whole line waits — and you can just passively accept each supplier’s lead time.

Four things you gain with one-stop integration

One drawing fixes the interfaces Board size → lining slots → rack slot pitch → drawer clearance → cart body outline → AGV underside: one dimension chain calculated in one go.
ESD grades aligned in one go Contact surfaces (foam, reel trays, racks, turnover boxes) fall within the same dissipative range, while grounding chains and conductive casters are selected to the low-resistance requirement of the discharge path — the specifications of both sections aligned in one go.
One contact, one acceptance The cart body and accessories are accepted as a complete set once assembled — no arriving in batches, no inspecting in batches, no arguing in batches.
Changing just what needs changing at a revision The cart body is the platform, the shelves are the interface, the linings are consumables — when the product changes generation, change the linings, not the whole cart.

We are not asking you to buy everything from us — we are reminding you: when you buy separately, who calculates those interfaces?

What we make, and what we help you find

To be honest, some equipment is outside our manufacturing scope. Our manufacturing scope is sheet metal, aluminum extrusion and structural parts — category ① below is mainly structural parts, which we make in-house and have project records for; the latter three categories belong respectively to precision lifting equipment, fluid measurement and electrical engineering, which we do not make, and the AGV chassis maker does not make them either (its product line is mobile chassis and navigation and dispatch). We do not earn from the latter three categories, but we will attach descriptions of each category’s use and a list of suppliers, and help match specifications — because equipment whose specifications do not match will in the end still come back to the cart interface.

● Made in-house by Jiahon ・ project records available

● Made in-house by Jiahon ・ project records available.

Scissor lift platform

Roller tracks added to the platform surface, at the same height as the cart for handover. Load rating ≥ 2.5 t (for a full rack of about 2 t, with a safety factor of 1.25). Used to eliminate the height difference between the conveying surface and the pallet.

○ Suggested category

○ Suggested category.

Server loading lift

8-GPU-class server nodes commonly weigh about 95–107 kg (depending on each server maker’s specifications) and have to be lifted into a 2.5 m rack. This is specialized lifting equipment, not a sheet metal part.

○ Suggested category

○ Suggested category.

Liquid-cooling leak testing ・ filling equipment

Blind-mated quick connectors and coolant filling: leak testing is a checkpoint before shipment. This is fluid measurement equipment and needs calibration by the equipment maker.

○ Suggested category

○ Suggested category.

Burn-in power infrastructure

Liquid-cooled AI racks have a far higher power density than conventional air-cooled racks. This is electrical engineering and requires certification by a licensed electrical engineer.

Our role: filling the gap, not taking over

Brand-new development from zero is not the role we hope to play. You give the sketch, the requirements and the priorities; we fill in the part you are short of.

Your company leads

  • Concept, sketch, requirements and priorities

  • The final say on drawing sign-off

  • What should be done and what is done first — decided by your company

Jiahon fills the gap

  • Turn the sketch into a drawing that can be built

  • Turn the drawing into something the production line can use

  • Fix the problems that turn up in use — changed directly in our own plants

What filling the gap looks like — taking “choosing a caster” as an example

Rating per caster ≥ (total load × 1.5) ÷ 3

Why divide by 3 and not 4 — when the floor is uneven, we assume one wheel is off the ground. Taking 1.5 here is meant to cover both dynamic impact and one wheel off the ground; the 1.25 taken for the lift platform earlier is a coefficient for static load, and the two rest on different grounds.

Then we give a primary and a backup option With candidate model numbers, wheel diameter, material, total mounting height, sales channel and lead time, and each option’s points of attention marked — for example, switching to a larger wheel increases the overall height, so the leveling feet must be lengthened accordingly and the drawing dimensions changed with them.

After that we write: “The formal design and model numbers follow the drawings issued by your company; we build and purchase according to the drawings.”

Three steps to start — no need to hold a specification meeting first, and no need to send purchasing for sign-off first

STEP 1

STEP 1.

Give us a sketch

Board / rack dimensions and weight, or a photo of the production line, or a hand-drawn sketch.

STEP 2

STEP 2.

We produce the drawing and quotation

Specification drawing + quotation, with dimensions, tier spacing, casters and grounding all marked; production starts just after the drawing is confirmed.

STEP 3

STEP 3.

Sample cart on the production line

A sample cart can be arranged for actual use on your production line for a period of time; please inquire with sales about the terms; if it does not suit you, that does not affect our dealings.

FAQ

Should production line carts be custom-made or bought off the shelf?

The deciding points are “whether the boards will change” and “the weight class”. Where a standard product can solve it, use the standard series — standard models, minor modifications possible; for stock and lead time please inquire. But as soon as any one of the following appears, it should be custom-made: a single item exceeding the load class of off-the-shelf products, tier spacing that must match a specific board height, a need for batch isolation with one batch per compartment, or a future connection to AGVs. The added cost of customization is usually far lower than the long-term cost of “buying an off-the-shelf product but spending two extra motions every day”.

We have bought all the anti-static (ESD) equipment — why do we still have static problems?

Because ESD is a continuous discharge path, not a collection of parts. Board → EVA lining → reel tray / rack → turnover box → cart body → grounding chain → casters → floor: as long as one link in between is an insulator, the whole chain is broken. Note that the two sections have different requirements: surfaces in contact with the board need to fall within the dissipative range of 10⁶–10⁹ Ω (to avoid sudden discharge), while the section from the grounding chain to the floor requires low-resistance conduction. A common break point is the casters — ordinary PU casters are effectively insulating. We recommend re-measuring the contact surfaces quarterly with a surface resistance meter, verifying the grounding path according to ANSI/ESD S20.20, and adding a multi-channel grounding alarm for real-time monitoring.

We are not bringing in AGVs yet — do carts need to be made AGV-ready now?

We recommend it. Building it in is mainly a matter of dimensions and datums — mark the under-cart clearance, lifting contact surface, positioning datums and frame rigidity for lifting conditions when the drawing is issued, and the added cost is limited; but adding it afterwards amounts to remaking the whole cart frame. In practice, under-ride lifting and under-ride towing types have different requirements for the cart underside (cart height, clearance and lifting stroke all differ), so the AGV model should be selected first before the drawing is made. Pushing everything by hand today is entirely fine; just keep the architecture in place.

A 2.5-meter-tall rack tilts when pushed onto a pallet — is it because the operators are not careful enough?

Mostly not. The critical tipping angle θ = arctan (support half-distance ÷ center-of-gravity height) depends just on geometry. Calculated for a top-heavy configuration with a support half-depth of 534 mm and a center-of-gravity height of 1.67 meters, the travel-direction critical angle is 17.8°; while on this trip onto the pallet, the bridge plate slope (estimated with a pallet height of 150 mm and a plate length of 0.9 meters, about 9.6°) plus one sudden stop (taking 0.2 g, equivalent to 11.3°) uses up 20.9°. That missing 3.1° cannot be made up however careful the operators are. To solve it, you have to tackle structure and process: eliminate the height difference (a lift platform set to the same height), or simply make the “onto the pallet” step disappear (the base is the pallet; the rack rolls in on level ground, then is locked and crated). See the full analysis in this article’s case study.

Foam, trays, drawer carts — which carrier is better?

There is no absolute better or worse; it is a trade-off between protection level, batch isolation and pick-and-place speed. For high-value single boards and shipping protection choose custom EVA foam (die-cut to the board, form-fitting enclosure; high protection level but slow pick-and-place); for high volume and automated loading choose trays (low unit price, standardized positioning); for in-plant turnover and mixed lines with multiple batches choose drawer carts (one batch per compartment, fast one-handed pull-out, no consumables). The three can also be mixed, for example with foam lining inside drawers.

What is the real difference between integrated purchasing and comparing prices separately?

The difference is in the interfaces. When buying separately, every interface (box ↔ rack, rack ↔ cart, cart ↔ AGV underside, the resistance of each ESD section) is the boundary between two suppliers, and no one is responsible for the whole; when problems occur they blame each other, and lead times each go their own way. Buying integrated means one drawing calculates the dimension chain in one go, ESD grades are aligned in one go, there is one contact and one acceptance, and at a revision you change just the linings, not the whole cart. The unit price is not necessarily lower; what you save is the cost of things “not fitting”.

How should an anti-static cart supplier be chosen?

Look at three things: first, whether the whole ESD discharge path takes care of the casters (ordinary PU casters are effectively insulating; conductive casters are needed); second, whether specifications can be set according to board size and weight; third, whether production starts just after the specification drawing is confirmed. Jiahon’s custom carts are made in-house at the Zhunan and Toufen plants in Miaoli, with production starting just after the drawing is confirmed; for project records see Custom cart overall proposal (five project cases).

If I want to look directly at the existing standard cart models, which are there?

Drawer type: 12-tier stainless steel drawer cart, 7-tier anti-static drawer cart; server boards in tiers: 8-tier server test cart; vibration-sensitive: stainless steel shock-absorbing cart series; AGV docking: AGV automatic turnover cart; cleanroom handling: stainless steel handling trolley; usable as a workbench: aluminum extrusion anti-static workbench cart.

Need us to help fill the gap?

After an inquiry, a tipping simulation report can be delivered based on your company’s actual configuration (please inquire with sales about schedule and fees); an on-site scale test can also be arranged. Or, you can start by giving us a sketch.